VRV Water-to-air heat pump

31 + Stage 2 heat recovery between outdoor units Domestic hot water Low temp. radiator Low temp. radiator Air handling unit Underfloor heating Underfloor heating Extracted heat delivers free hot water and heating Cooling Hot water Heating 25°C - 35°C 25°C - 35°C 45°C - 75°C 25°C - 45°C 25°C - 75°C 45°C - 75°C Domestic hot water tank Daikin solar panel VRV indoor units Heating only hydrobox for VRV or Reversible low temperature hydrobox BS-Box BS-Box Cooling tower (Closed type), boiler Heat rejected to loop Heat absorbed from loop Heat rejected to loop Heat absorbed from loop * Above system configuration are for illustration purpose only. Liquid pipe Gas pipe Hot water Discharge gas pipe Stage 1 heat recovery between indoor units RWEYQ-T9 Outdoor unit system RWEYQ 16T9 18T9 20T9 22T9 24T9 26T9 28T9 System Outdoor unit module 1 RWEYQ8T RWEYQ10T RWEYQ12T RWEYQ14T Outdoor unit module 2 RWEYQ8T RWEYQ10T RWEYQ12T RWEYQ14T Capacity range HP 16 18 20 22 24 26 28 Cooling capacity Prated,c kW 44.8 50.4 56.0 61.5 67.0 73.5 80.0 Heating capacity Prated,h kW 50.0 56.5 62.5 69.0 75.0 82.5 90.0 Max. 6°CWB kW 50.0 56.5 62.5 69.0 75.0 82.5 90.0 Recommended combination 4 x FXMQ63P7VEB + 2 x FXMQ80P7VEB 4 x FXMQ50P7VEB + 4 x FXMQ63P7VEB 8 x FXMQ63P7VEB 6 x FXMQ50P7VEB + 4 x FXMQ63P7VEB 12 x FXMQ50P7VEB 7 x FXMQ50P7VEB + 5 x FXMQ63P7VEB 2 x FXMQ50P7VEB + 10 x FXMQ63P7VEB ηs,c % 307.6 308.7 298.1 311.3 342.6 322.5 306.1 ηs,h % 459.2 491.1 466.8 447.9 434.5 406.9 387.9 SEER 7.9 7.7 8.0 8.8 8.3 7.9 SCOP 11.7 12.5 11.9 11.4 11.1 10.4 9.9 Maximum number of connectable indoor units 64 (1) Indoor index connection Min. 200.0 225.0 250.0 275.0 300.0 325.0 350.0 Max. 600.0 675.0 750.0 825.0 900.0 975.0 1,050.0 Piping connections Liquid OD mm 12.7 15.9 19.1 Gas OD mm 28.6 34.9 HP/LP gas OD mm 22.2 / 28.6 28.6 / 28.6 28.6 / 34.9 Total piping length System Actual m 500 Power supply Phase/Frequency/Voltage Hz/V 3N~/50 /380-415 Current - 50Hz Maximum fuse amps (MFA) A 32 35 40 50 Outdoor unit system RWEYQ 30T9 32T9 34T9 36T9 38T9 40T9 42T9 System Outdoor unit module 1 RWEYQ10T RWEYQ12T RWEYQ14T Outdoor unit module 2 RWEYQ10T RWEYQ12T RWEYQ14T Outdoor unit module 3 RWEYQ10T RWEYQ12T RWEYQ14T Capacity range HP 30 32 34 36 38 40 42 Cooling capacity Prated,c kW 84.0 89.5 95.0 100.5 107.0 113.5 120.0 Heating capacity Prated,h kW 94.5 100.5 106.5 112.5 120.0 127.5 135.0 Max. 6°CWB kW 94.5 100.5 106.5 112.5 120.0 127.5 135.0 Recommended combination 12 x FXMQ63P7VEB 6 x FXMQ50P7VEB + 8 x FXMQ63P7VEB 12 x FXMQ50P7VEB + 4 x FXMQ63P7VEB 18 x FXMQ50P7VEB 13 x FXMQ50P7VEB + 5 x FXMQ63P7VEB 8 x FXMQ50P7VEB + 10 x FXMQ63P7VEB 3 x FXMQ50P7VEB + 15 x FXMQ63P7VEB ηs,c % 308.3 318.2 342.5 352.3 338.8 341.4 332.9 ηs,h % 467.2 456.1 447.0 438.5 419.4 404.4 391.2 SEER 7.9 8.2 8.8 9.0 8.7 8.5 SCOP 11.9 11.6 11.4 11.2 10.7 10.3 10.0 Maximum number of connectable indoor units 64 (1) Indoor index connection Min. 375.0 400.0 425.0 450.0 475.0 500.0 525.0 Max. 1,125.0 1,200.0 1,275.0 1,350.0 1,425.0 1,500.0 1,575.0 Piping connections Liquid OD mm 19.1 Gas OD mm 34.9 41.3 HP/LP gas OD mm 28.6 / 34.9 28.6 / 41.3 41.3 / 34.9 Total piping length System Actual m 500 Power supply Phase/Frequency/Voltage Hz/V 3N~/50 /380-415 Current - 50Hz Maximum fuse amps (MFA) A 50 63 80 (1)Actual number of units depends on the indoor unit type (VRV DX indoor, RA DX indoor, etc.) and the connection ratio restriction for the system (being; 50% ≤ CR ≤130%). | Contains fluorinated greenhouse gases * EU member states, UK, Bosnia-Herzegovina, Serbia, Montenegro, Kosovo, Albania, North Macedonia, Iceland, Norway, Switzerland

RkJQdWJsaXNoZXIy MTE0MTkzMg==