100 EPSK-A Outdoor Unit EPSK 08AW1 10AW1 06AV3 08AV3 10AV3 12AW1 14AW1 Dimensions Unit HeightxWidthxDepth mm 1,123x1,330x604 Weight Unit kg 178 174 191 Compressor Quantity 1 Type Hermetically sealed scroll compressor Operation range Cooling Min.~Max. °CDB 10 ~43 Domestic hot water Min.~Max. °CDB -28 ~40 Refrigerant Type R-290 GWP 3 Charge kg 1 1.25 Control Expansion valve Sound power level Heating Nom. dBA 45 (1) 47 (1) 45 (1) 47 (1) 52 (1) Cooling Nom. dBA 53 53.2 (2) 52.2 (2) 53 53.2 (2) 62 63 Sound pressure level Heating Nom. dBA 32.4 (1) 32.8 (1) 32.6 (1) 32.4 (1) 32.8 (1) 38 Cooling Nom. dBA 37.2 (2) 37.3 (2) 36.9 (2) 37.2 (2) 37.3 (2) 47 48 Power supply Name/Phase/Frequency/Voltage Hz/V W1/3~/50/400 V3/1~/50/230 W1/3~/50/400 Current Recommended fuses A 16 25 16 (1)Measured at LWC 47-55°C; Ta DB/WB 7°C/6°C. | (2)Measured at LWC 12-7°C; Ta 35°C. | 1 1/4" field piping | 1 1/2" field piping Daikin Altherma 4 H J Best-in-class heating capacity, ensuring warmth at cold ambient J Outdoor unit extracts heat from the outdoor air, even at -28°C J By heat pump operation only, the outdoor unit delivers a leaving water temperature of 70-75°C at -15°C ambient temperature J Ultra low sound level of 50-54 dBA J Choosing natural refrigerant R-290 product reduces the environmental impact, leading to lower energy consumption EPSK08-10AW1 / EPSK06-10AV3 / EPSK12-14AW1 R-290 up to 75 °C up to LWT 75°C at -15°C At 35°C average climate At 55°C average climate +++ D A+++ + F A+ Whisper quiet Onecta app Guaranteed operation down to -28°C
RkJQdWJsaXNoZXIy MTE0MTkzMg==