103 R-290 up to up to 75 °C LWT 75°C at -15°C At 35°C average climate At 55°C average climate Whisper quiet Onecta app Guaranteed operation down to -28°C EPSK06-14AV3/W1 EPVX10-14A4V/9W EPVX10-14A4V/9W + EPSK06-14AV3/W1 Daikin Altherma 4 H F Floor standing air to water heat pump for heating, cooling and hot water J New intuitive MMI 5” touchscreen for better user experience J Inclusion of all hydraulic components means no third party components are required J PCB board and hydraulic components are located in the front for easy access J A combined stainless steel domestic hot water tank of 180 or 230L and heat pump for easy installation J Integrated back-up heater of 4.5 or 9 kW EPSK06-10AV3 EPSK08-10AW1 EPSK12-14AW1 EPVX10A4V EPVX10A9W EPVX14A4V EPVX14A9W Efficiency data EPVX + EPSK 10S18/S23A4V/9W + 06AV3 10S18/S23A4V/9W + 08AV3 10S18/S23A4V/9W + 10AV3 10S18/S23A4V/9W + 08AW1 10S18/S23A4V/9W + 10AW1 14S18/S23A4V/9W + 12AW1 14S18/S23A4V/9W + 14AW1 Heating capacity Nom. kW 5.81 7.62 8.11 7.62 8.11 10.2 Power input Heating kW 1.12 1.52 1.64 1.52 1.64 1.86 Space heating Average climate water outlet 55°C General SCOP 3.91 3.97 4.02 3.94 3.99 4.04 3.84 ηs (Seasonal space heating efficiency) % 153 156 158 155 157 159 150 Seasonal space heating eff. class Prated at -10°C kW 6.5 7.5 8.5 7.5 8.5 10.5 14 Average climate water outlet 35°C General SCOP 5.12 5.15 5.14 4.96 ηs (Seasonal space heating efficiency) % 202 203 202 203 195 Seasonal space heating eff. class Prated at -10°C kW 6.5 7.5 8.5 7.5 8.5 10 12 Domestic hot water heating General Declared load profile L Average climate COPdhw 2.93 2.91 3.03 ηwh (water heating efficiency) % 117 116 121 Water heating energy efficiency class Indoor Unit EPVX 10S18/S23A4V/9W 14S18/S23A4V/9W Casing Colour White Material Precoated galvanized steel + plastic Dimensions Unit HeightxWidthxDepth mm 1,650x595x625/1,850x595x625 Weight Unit kg 94.0/111 Tank Water volume l 180/230 Maximum water temperature °C 0.00 Maximum water pressure bar 10 Corrosion protection Pickling Operation range Indoor installation Ambient Min. - Max. °CDB 5~35 (3) Heating Water side Min.~Max. °CDB 15~70 15~75 Domestic hot water Water side Min.~Max. °CDB 10~75 Sound power level Nom. dBA 45.0 (1) Sound pressure level Nom. dBA 31.0 (2) Outdoor Unit EPSK 06AV3 08AV3 10AV3 08AW1 10AW1 12AW1 14AW1 Dimensions Unit HeightxWidthxDepth mm 1,123x1,330x604 Weight Unit kg 174 178 191 Compressor Quantity 1 Type Hermetically sealed scroll compressor Operation range Heating Min.~Max. °CDB -28~25 Cooling Min.~Max. °CDB 10~43 Domestic hot water Min.~Max. °CDB -28~40 Refrigerant Type R-290 GWP 3 Charge kg 1 1.25 Charge tCO2Eq 0.003 0.0038 Control Expansion valve Sound power level Heating Nom. dBA 45 (4) 47 (4) 45 (4) 47 (4) 52 (4) Cooling Nom. dBA 52.2 (5) 53 (5) 53.2 (5) 53 (5) 53.2 (5) 62 (5) 63 (5) Sound pressure level Heating Nom. dBA 32.6 (4) 32.4 (4) 32.8 (4) 32.4 (4) 32.8 (4) 38 (4) Cooling Nom. dBA 36.9 (5) 37.2 (5) 37.3 (5) 37.2 (5) 37.3 (5) 47 (5) 48 (5) Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3~/50/400 Current Recommended fuses A 25 16 (1)Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. | (3)Depends on operation mode, refer to installation manual. | (4)Measured at LWC 47-55°C; Ta DB/WB 7°C/6°C. | (5)Measured at LWC 12-7°C; Ta 35°C. | Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB | Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB | Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). | Based on dT of 45 K | Minimum required volume, excluding the volume in the unit | Refer to operation range of the unit. | Above mentioned power supply of the hydrobox is for the backup heater only. The switch box and the pump of the hydrobox are supplied via the outdoor unit. The optional domestic hot water tank has a separate power supply. | Refer to wiring diagram and installation manual for correct recommended fuse depending on power supply and grid connection | 1 1/4" field piping | 1 1/2" field piping | Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C | Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 BRC1HHDK(7) 011-1W0929 011-1W0930 011-1W0931 011-1W0933 011-1W0934 011-1W1097
RkJQdWJsaXNoZXIy MTE0MTkzMg==