117 011-1W0501 011-1W0502 ETSH12E EPRA08-12EV3 EPRA08-12EW1 Efficiency data ETSH + EPRA 12P30E + 08EV/W 12P50E + 08EV/W 12P30E + 10EV/W 12P50E + 10EV/W 12P30E + 12EV/W 12P50E + 12EV/W Space heating Average climate water outlet 55 °C General SCOP 3.41/3.52 3.43/3.53 ŋs (Seasonal space heating efficiency) % 134/138 Seasonal space heating eff. class ++ D A+++ Average climate water outlet 35 °C General SCOP 4.69/4.81 4.71/4.84 4.71/4.84 ŋs (Seasonal space heating efficiency) % 184/190 186/191 186/191 Seasonal space heating eff. class +++ D A+++ Domestic hot water heating General Declared load profile L Average climate COPdhw 2.75/2.83 3.10/3.17 2.75/2.83 3.10/3.17 2.75/2.83 3.10/3.17 ŋwh (water heating efficiency) % 116/119 128/131 116/119 128/131 116/119 128/131 Water heating energy efficiency class + F A+ Indoor Unit ETSH 12P30E 12P50E 12P30E 12P50E 12P30E 12P50E Casing Colour Traffic white (RAL9016) / Traffic black (RAL9017) Material Impact resistant polypropylene Dimensions Unit HeightxWidthxDepth mm 1,892x594x644 1,910x792x816 1,892x594x644 1,910x792x816 1,892x594x644 1,910x792x816 Weight Unit kg 75 98 75 98 75 98 Tank Water volume l 294 477 294 477 294 477 Maximum water temperature °C 85 Operation range Heating Ambient Min.~Max. °C -28 ~ 25 Water side Min.~Max. °C 18 ~ 65 Domestic hot water Ambient Min.~Max. °C -28 ~ 35 Water side Min.~Max. °C 10 ~ 63 Sound power level Nom. dBA 47.30 Sound pressure level Nom. dBA 38.60 Outdoor Unit EPRA 08EV3/W1 10EV3/W1 12EV3/W1 Dimensions Unit HeightxWidthxDepth mm 1,003x1,270x533 Weight Unit kg 118 Compressor Quantity 1 Type Hermetically sealed swing compressor Operation range Heating Min.~Max. °CDB -28 ~ 25 Domestic hot water Min.~Max. °CDB -28 ~ 35 Refrigerant Type R-32 GWP 675 Charge kg 3.25 Charge TCO2Eq 2.19 Control Expansion valve LW(A) Sound power level (according to EN14825) 53 Sound pressure level (at 1 meter) Nom. 40.60/41.10 Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 - W1/3~/50/400 Current Recommended fuses A 32/16 This product contains fluorinated greenhouse gases. Daikin Altherma 3 H MT ECH2O Floor standing air-to-water heat pump for heating and hot water with thermal solar support › Integrated solar unit, offering top comfort in heating and hot water › Maximum use of renewable energy: uses heat pump technology for heating and solar support for space heating and domestic hot water production › Fresh water principle: hygienic water, with no need for thermal legionella disinfection › Maintenance-free tank: no corrosion, anode, scale or lime deposits, and no loss of water through safety valve › Solar support of domestic hot water with pressureless (drain-back) solar system ETSH12E + EPRA08-12EV3/W1 EPRA08-12EV3/W1 ETSH12E BRC1HHDW 65 °C up to +++ D A+++ + F A+ Solar panel Fresh hot water Voice control Onecta app Guaranteed operation down to -28°C
RkJQdWJsaXNoZXIy MTE0MTkzMg==