128 ELVH-E6V ELVH-E9W ERRA08-12EW1 ERRA08-12EV3 Efficiency data ELVH + ERRA 12S18/23E6V/9W + 08EV3 12S18/23E6V/9W + 10EV3 12S18/23E6V/9W + 12EV3 12S18/23E6V/9W + 08EW1 12S18/23E6V/9W + 10EW1 12S18/23E6V/9W + 12EW1 Heating capacity Nom. kW 6.17 Power input Heating kW 1.25 1.21 Space heating Average climate water outlet 55°C General SCOP 3.34 3.44 3.42 3.43 3.53 ηs (Seasonal space heating efficiency) % 130 131 135 134 138 Seasonal space heating eff. class Prated at -10°C kW 12.5 Average climate water outlet 35°C General SCOP 4.69 4.71 4.81 4.84 ηs (Seasonal space heating efficiency) % 184 186 190 191 Seasonal space heating eff. class Prated at -10°C kW 8.3 Domestic hot water heating General Declared load profile L Average climate COPdhw 2.72/2.96 2.80/3.05 ηwh (water heating efficiency) % 117/126 120/130 Water heating energy efficiency class Indoor Unit ELVH 12S18/23E6V/9W Casing Colour White + Black Material Precoated sheet metal Dimensions Unit HeightxWidthxDepth mm 1,655x595x634/1,855x595x634 Weight Unit kg 120/129 Tank Water volume l 180/230 Maximum water temperature °C 70.0 Maximum water pressure bar 10 Corrosion protection Pickling Operation range Indoorinstallation Ambient Min.~Max. °CDB 5~35 Heating Water side Min.~Max. °CDB 15~65 Domestic hot water Water side Min.~Max. °CDB 25~62 Sound power level Nom. dBA 44.0 Sound pressure level Nom. dBA 30.0 Outdoor Unit ERRA 08EV3 10EV3 12EV3 08EW1 10EW1 12EW1 Dimensions Unit HeightxWidthxDepth mm 1,003x1,270x533 Weight Unit kg 107 Compressor Quantity 1 Type Hermetically sealed swing compressor Operation range Heating Min.~Max. °CDB -25.0~25 Cooling Min.~Max. °CDB 10~43 Domestic hot water Min.~Max. °CDB -25~35 Refrigerant Type R-32 GWP 675.0 Charge kg 3.25 Charge tCO2Eq 2.19 Control Expansion valve Sound power level Heating Nom. dBA 56.0 56.0 (1) Cooling Nom. dBA 60.1 60.6 61.5 61.2 61.4 (2) 60.9 (2) Sound pressure level Heating Nom. dBA 40.6 41.1 41.1 (3) Cooling Nom. dBA 47 47.4 48.5 47.1 47.1 (4) 47.2 (4) Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3~/50/400 Current Recommended fuses A 32 16 (1)Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (2)Condition 2: cooling Ta 35°C - LWE 7°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (3)Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings. | (4)The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Condition: Ta 35°C - LWE 7°C (DT = | Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C | Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 | Test at Ta DB/WB 7°C/6°C. According to EN 16147. | DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed | Operation area is extended to lower flow rates depending on operation mode - refer to ESP curve. | Based on a dT of 45 K | Including piping + PHE + back-up heater; excluding expansion vessel | Measured with a pressure drop of 10 kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. | For more details, see operation range drawing | 4 pole 20 A curve 400V tripping class C (refer to wiring diagram) Daikin Altherma 3 R MT F Floor standing air to water heat pump for heating and hot water J A combined stainless steel domestic hot water tank of 180 or 230L and heat pump for easy installation J Energy efficient heating only system based on air to water heat pump technology J Quick configuration in 9 steps in a high resolution colour interface wizard J Inclusion of all hydraulic components means no third party components are required J The unit’s sleek design blends in with other household appliances. 011-1W0651 011-1W0652 011-1W0653 011-1W0654 011-1W0655 011-1W0656 ERRA08-12EW1 ELV(H-X)-E6V_E9W 65 °C up to 011-1W0651 011-1W0652 011-1W0653 011-1W0654 011-1W0655 011-1W0656 Voice control Onecta app Guaranteed operation down to -25°C ELVH-E6V/9W + ERRA08-12EV3/EW1 BRC1HHDW(7)
RkJQdWJsaXNoZXIy MTE0MTkzMg==