03_ECPEN25-500_Heating

96 Sealed Switchbox: J Placed away from the refrigerant connections, on top of the fan J The full sealing prevents R-290 to get inside the switchbox Highest safety standards in the industry At Daikin, safety is our top priority. The Daikin Altherma 4 H heat pump is designed to set new industry safety standards, incorporating advanced features such as a high‑efficiency gas separator and factory-mounted anti-freeze valves. These components, developed specifically for Daikin, ensure unparalleled safety and performance. Gas leak sensor: J Detects potential refrigerant leaks J In case of leak detection, sensor automatically triggers the fan to run at maximum speed, effectively ventilating the area to prevent the buildup of a flammable gas cloud. J Minimum hourly self-inspection check, ensuring ongoing protection. Refrigerant vessel: J Protects refrigerant against possible damage during storage and transportation, that might cause leakages J After installation, R-290 is released into the refrigerant cycle J It can survive a 10 metres drop without leakage