462 Indoor units FCAHG-H FCAG-B FFA-A9 FDXM-F9 FBA-A(9) Panels Decoration panel (obligatory for cassette units, optional for others) Standard panels: BYCQ140E (white) / BYCQ140EW (full white)(1) / BYCQ140EB (black) Auto cleaning panels(2) (4): BYCQ140EGF (white) / BYCQ140EGFB (black) Designer panels: BYCQ140EP (white) / BYCQ140EPB (black) BYFQ60C2W1W (white panel) BYFQ60C2W1S (grey panel) BYFQ60B3W1 (standard panel) Panel spacer for reducing required installation height KDBQ44B60 (only for standard panel) Sealing kit for 3- or 2-directional air discharge KDBHQ56B140 (11) BDBHQ44C60 Sensor kit BRYQ140B (white) BRYQ140BB (black) BRYQ140C (white designer) BRYQ140CB (black designer) BRYQ60AW (white)(9) BRYQ60AS (silver)(9) Individual control systems Onecta app BRP069C82 (14) (18) BRP069C81 (18) BRP069C81 BRP069C81 (18) Infrared remote control (incl. receiver) BRC7FA532F (white) (11) (16) BRC7FA532FB (black) (11) (16) BRC7FB532F (designer white) (11) (16) BRC7FB532FB (designer black) (11) (16) BRC7EB530W for standard panel (5)(6) BRC7F530W for white panel (5)(6) BRC7F530S - for silver panel (5)(6) BRC4C65 BRC4C65 Madoka BRC1H52W (9) (White) / BRC1H52S (9) (Silver) / BRC1K552K (9) (Black) User-friendly wired remote controller with premium design • • • • BRC1E53A/B/C (3) (13) - Wired remote controller with full-text interface and back-light • • • • Centralised control systems DIII-net connection - for connection to centralized control standard standard standard standard DCC601A51 - intelligent Tablet Controller • • • • DCS601C51 (13) - intelligent Touch Controller • • • • DCS302C51 (13) - Central remote controller • • • • DCS301B51 (13) - Unified ON/OFF controller • • • • Building Management System & Standard protocol interfaces for individual control EKMBPP1 - Modbus interface for monitoring and control • • • • RTD-10 - Modbus interface for infrastructure cooling • • • • RTD-20 - Modbus interface for retail • • • • RTD-HO - Modbus interface for hotel • • • • KLIC-DI_V2 - KNX Interface • • • • for central control DCM601B51 - intelligent Touch Manager • • • • DGE601A51 - Edge adapter for connection to Daikin Cloud Plus • • • • DGE602A51 - Edge lite adapter for connection to Daikin Cloud Plus • • • • EKMBDXB - Modbus interface • • • • DCM010A51 - Daikin PMS interface • • • • DMS502A51 - BACnet Interface • • • • DMS504B51 - LonWorks Interface • • • • Filters Auto cleaning filter see deco panel BAE20A62 (25 - 35) BAE20A102 (50 - 60) UV Streamer kit (purifies the air of pollutants such as virusses, bacteria, fine dust, odours, allergens, etc ensuring a healthy indoor environment) UV Streamer kit BAEF125AWB (22) Replacement filter BAF55A125 High efficiency filter ePM10 60% BAF552AA160 (23) (BAF552AA160-5: box of 5 filters) (BAF552AA160-10: box of 10 filters) Replacement long-life filter, non-woven type KAF5511D160 KAF441C60 Filter chamber Wiring and sensors Extension wire auto cleaning panel (required when auto cleaning panel AND Onecta app are both installed) KRCS - External wired temperature sensor KRCS01-5B KRCS01-4 KRCS01-4 KRCS01-4 K.RSS - External wireless temperature sensor SB.K.RSS_RFC (EKEWTSC-2 + K.RSS) • • Wiring and sensors Adapters Wiring adapter with 2 output signals (compressor/ Error, Fan output) KRP1BA58 (10)(11) KRP1B57 (10) KRP1B56 (10) Adapter (interlock for fresh air intake fan) KRP1B54 Adapter with 4 output signals (compressor / Error, Fan, Aux., heater, Humidifier output) EKRP1C12 (10)(11) EKRP1B2 EKRP1B2 (7) Adapter for centralised external monitoring/control (controls 1 entire DIII-NET system) KRP2A53 (10) KRP2A51 (7)(10) Adapter for centralised external monitoring/control via dry contacts and setpoint control via 0-140Ω (for dedicated indoor) KRP4A53 (10)(11)(17) KRP4A51 KRP4A54-9 KRP4A52 (10) Adapter for keycard and/or window contact connection (in combination with BRC1H*, BRC1/2/3E* only) BRP7A53 BRP7A53 BRP7A54 (10) BRP7A51 (12) Installation box/Mounting plate for adapter PCBs (when there is no space in the switchbox, an installation box is required) KRP1H98A (11) KRP4A93 KRP1BC101 KRP1BC101 Wiring kit for Remote ON/OFF or Forced OFF standard standard standard standard Others Drain pump kit Multi zoning kit (for detailed model code overview refer to multizoning argue card in this catalogue) • • L-type piping kit (upward direction) Fresh air intake kit (direct installation type) KDDP55C160-1 (chamber) KDDP55D160-2 (diffuser) (11) KDDQ44XA60 Air discharge adapter for round duct KDAP25A56A (35-50) KDAP25A71A (60-71) KDAP25A140A (100-140) (1) Dirt formation is more easily visible on white insulation. It is recommended not to install this option in environments with a high concentration of dirt. (2) To be able to control option BYCQ140EG(F)/EGFB, controller BRC1H*, BRC1E* is needed. These options cannot be combined with RXYSQ*, multi or non-inverter split units (3) Included languages are: A: English, German, French, Dutch, Spanish, Italian and Portuguese B: English, Bulgarian, Croatian, Czech, Hungarian, Romanian and Slovenian C: English, Greek, Polish, Russian, Albanian, Slovak and Turkish (4) The option is intended exclusively for use in fine dust enviornments (e.g. Clothing shops). Do not use it in environments that are greasy or have high humidity. F = finer mesh (5) Sensing function is not available (6) Individual flap control function not available (7) If installing an electrical heater, an option PCB for external electrical heater (EKRP1B2) for each indoor unit is required. These options require mounting plate KRP4A96. Electrical heaters and humidifiers are field-supplied. Do not install them inside the equipment. (8) Mounting plate KRP4A96 is required for these options. Maximum 2 option PCB’s can be mounted. (9) This option cannot be used with RR and RQ models Options - Sky Air
RkJQdWJsaXNoZXIy MTE0MTkzMg==