10_ECPEN26-500_Chillers

692 EWYE-CZP EWYE-CZP Heating & Cooling EWYE-CZP 019 022 025 030 035 050 060 070 SEER 3.877 3.943 4.07 4.595 4.655 4.222 4.415 4.661 Space heating Average climate water outlet 35°C General SCOP 3.999 4.38 3.872 4.058 Seasonal space heating eff. class A++ Cooling capacity Nom. kW 14.884 16.421 18.242 22.448 25.663 42.106 46.9 59.618 Heating capacity Nom. kW 18.212 20.25 23.931 29.721 34.351 49.887 59.575 73.267 Power input Cooling Nom. kW 5.393 6.026 6.643 7.394 8.901 15.694 17.86 22.354 Heating Nom. kW 5.85 6.507 7.658 8.923 10.563 16.351 20.34 24.422 Capacity control Method Inverter controlled Minimum capacity % 36 33 29 25 22 13 10 EER 2.76 2.725 2.746 3.036 2.883 2.683 2.626 2.667 COP 3.113 3.112 3.125 3.331 3.252 3.051 2.929 3 IPLV 4.863 4.873 4.985 5.454 5.389 5.055 5.087 4.987 Weight Unit kg 298 300 401 402 671 761 Operation weight kg 300 302 404 405 677 769 Water heat exchanger Type Brazed plate Water volume l 1.87 2.35 5.13 7.83 Water flow rate Cooling Nom. l/s 0.7 0.77 0.84 1.06 1.21 1.99 2.16 2.77 Heating Nom. l/s 0.87 0.97 1.11 1.42 1.61 2.35 2.77 3.45 Water pressure drop Cooling Nom. kPa 6.05 7.19 8.41 9.82 12.41 10.01 11.62 9.51 Heating Nom. kPa 9.03 10.89 13.77 16.4 20.53 13.57 18.38 14.38 Air heat exchanger Type Al Fins & Cu Tubes Compressor Type Scroll Quantity 1 2 Fan Type Axial Quantity 1 2 3 4 Air flow rate Cooling Nom. l/s 3,160 3,570 5,300 6,080 10,440 9,240 12,160 Heating Nom. l/s 2,770 3,180 5,340 6,130 8,110 9,310 10,680 Speed rpm 800 900 700 800 900 800 Sound power level Cooling Nom. dBA 82 83 86 Heating Nom. dBA 82 83 86 Sound pressure level Cooling Nom. dBA 66.197 67.137 67.227 66.683 66.676 68.822 68.855 68.528 Heating Nom. dBA 66.197 67.137 67.227 66.683 66.676 68.822 68.855 68.528 Refrigerant Type/GWP R-454C/145.5 Charge kg 6.6 9.7 16.3 21.2 Circuits Quantity 1 2 Piping connections Evaporator water inlet/outlet (OD) 1''1/4 (female) 2'' (female) Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB | Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB | Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | According to EN14825 | Depends on operation mode, refer to installation manual. | For more details, see operation range drawing Air to Water Inverter Heat Pump J Outdoor unit designed for cold and hot climates J Inverter heat pump J Available in 8 sizes J Daikin scroll compressor with Vapor Injection J Wide operating range: -25°C to +40 °C Ambient temperature and up to 70°C Hot Water Temperature J Daikin Tube & Fins (Cu/Al) Heat Exchanger ensures efficient heat transfer, durability, and long-term system reliability. J Stock Availability of Inverter Pump Configuration Mounted On-Board simplifies installation, improves system efficiency, and enables faster project turnaround. Scroll compressor Inverter technology

RkJQdWJsaXNoZXIy MTE0MTkzMg==