Sky Air product catalogue

153 35 2 1 0 C 5 ARROW VIEW C 340 0 - 6 7 5 4 - 8 M10 1 2 4 3 950 9 5 0 8 7 6 AB 2 1 3 O75 10 DETAIL A 7 8 0 710 420 9 420 DETAIL B 121.5 350 9 5 5 4 . 5 5 4 . 5 81 100 100 85 9 6 . 5 DETAIL B 350 121.5 DETAIL A FCAG100/125/140BVEB FCAHG71/100/125/140HVEB FXFQ80/100/125BVEB FXFA80/100/125A2VEB 81 100 100 85 8 0 1 0 0 1 0 0 8 0 54.5 54.5 96.5 2 5 . 4 1 2 1 . 5 3 5 0 95 67 53 1 2 1 . 5 2 5 . 4 3 5 0 8 0 1 0 0 1 0 0 8 0 96.5 9 6 . 5 5 3 FCAG35/50/60/71BVEB FXFQ20/25/32/40/50/63BVEB FXFA20/25/32/40/50/63A2VEB FCAG100/125/140BVEB FCAHG71/100/125/140HVEB FXFQ80/100/125BVEB FXFA80/100/125A2VEB A B 860 910 8 6 0 - 9 1 0 35 10°10° 256 (*3) (*2) Opposite side Opposite side ·2· places ·2· places Opposite side ·2· places Opposite side ·2· places 6 7 7 Suspension bolt OR 330 280 9 0 2 3 0 A A 4 0 ( 9 0 ) 2 5 5 FCAG35/50/60/71BVEB FXFQ20/25/32/40/50/63BVEB FXFA20/25/32/40/50/63A2VEB 55 840 55 840 500· r mo e 0· ore 500 more 15 · o A C ARROW VIEW C FCAG35/50/60/71BVEB FXFQ20/25/32/40/50/63BVEB FXFA20/25/32/40/50/63A2VEB FCAG100/125/140BVEB FCAHG71/100/125/140HVEB FXFQ80/100/125BVEB FXFA80/100/125A2VEB D1216 58D 35 2 1 0 C 5 ARROW VIEW C 340 0 - 6 7 5 4 - 8 M10 1 2 4 3 950 9 5 0 8 7 6 AB 2 1 3 O75 10 DETAIL A 7 8 0 710 420 9 420 DETAIL B 121.5 350 9 5 5 4 . 5 5 4 . 5 81 100 100 85 9 6 . 5 DETAIL B 350 121.5 DETAIL A FCAG100/125/140BVEB FCAHG71/100/125/140HVEB FXFQ80/100/125BVEB FXFA80/100/125A2VEB 81 100 100 85 8 0 1 0 0 1 0 0 8 0 54.5 54.5 96.5 2 5 . 4 1 2 1 . 5 3 5 0 95 67 53 1 2 1 . 5 2 5 . 4 3 5 0 8 0 1 0 0 1 0 0 8 0 96.5 9 6 . 5 5 3 FCAG35/50/60/71BVEB FXFQ20/25/32/40/50/63BVEB FXFA20/25/32/40/50/63A2VEB FCAG100/125/140BVEB FCAHG71/100/125/140HVEB FXFQ80/100/125BVEB FXFA80/100/125A2VEB A B 860 910 8 6 0 - 9 1 0 35 10°10° 256 (*3) (*2) Opposite side Opposite side ·2· places ·2· places Opposite side ·2· places Opposite side ·2· places 6 7 7 Suspension bolt OR 330 280 9 0 2 3 0 A A 4 0 ( 9 0 ) 2 5 5 FCAG35/50/60/71BVEB FXFQ20/25/32/40/50/63BVEB FXFA20/25/32/40/50/63A2VEB 55 840 55 840 500· r mo e 0· ore 500 more 15 · o A C ARROW VIEW C FCAG35/50/60/71BVEB FXFQ20/25/32/40/50/63BVEB FXFA20/25/32/40/50/63A2VEB FCAG100/125/140BVEB FCAHG71/100/125/140HVEB FXFQ80/100/125BVEB FXFA80/100/125A2VEB D1216 58D 35 35 1 3 0 C 5 ARROW VIEW C 0 - 6 7 5 1 7 5 1 0 4 0 4 - 8 M10 1 4 3 950 9 5 0 8 7 6 AB 2 1 3 O75 10 A DETAIL A 7 8 0 710 860 910 420 8 6 0 - 9 1 0 9 420 B DETAIL B 121 5 350 9 5 5 4 . 5 5 4 . 5 81 100 100 85 9 6 . 5 DETAIL B 350 121 5 DETAIL A 81 100 100 85 1 0 0 8 0 54 554 5 6 5 1 2 1 . 5 95 67 53 1 2 1 . 5 3 5 0 8 0 1 1 965 9 6 . 5 6 7 5 3 200 or ore 2 · or or r Opposite side ·2· places Opposite side ·2· places FCAG100/125/140BVEB FCAHG71/100/125/140HVEB FXFQ80/100/125BVEB FXFA80/100/125A2VEB FCAG35/50/60/71BVEB FXFQ20/25/32/40/50/63BVEB FXFA20/25/32/40/50/63A2VEB Opposite side ·2· places Opposite side ·2· places Suspension bolt OR 55 55 840 840 ·AD· or more A A 5 4 3 2 1 280 330 340 A C FCAG100/125/140BVEB FCAHG71/100/125/140HVEB FXFQ80/100/125BVEB FXFA80/100/125A2VEB ARROW VIEW C FCAG35/50/60/71BVEB FXFQ20/25/32/40/50/63BVEB FXFA20/25/32/40/50/63A2VEB Detailed technical drawings FCAG-B / FCAHG-H WITH STANDARD PANEL FCAG-B / FCAHG-H WITH AUTO CLEANING PANEL 2D121655D NOTES 1. Location of nameplate The unit nameplate is located on the control box cover. The decoration panel nameplate is located on the piping-side panel frame, under the corner cover. 2. When installing optional accessories, refer to their respective documentation. 3. Make sure the distance between the ceiling and the cassette does not exceed 35 mm. The maximum ceiling opening is 910 mm. 4. When the conditions in the ceiling exceed 30°C ambient temperature and 80% relative humidity, or when fresh air is inducted into the ceiling, additional insulation is required (polyethylene foam, thickness ≥ 10 mm) 5. When installing a sensor kit, there will be a sensor on this location. For details, see the drawing of the sensor kit. 6. When installing a wireless controller, there will be a receiver on this location. For details, see the drawing of the wireless controller. Item Name 1 Liquid pipe connection port 2 Gas pipe connection port 3 Drain pipe connection 4 Power supply wiring intake 5 Transmission wiring intake hole 6 Air discharge outlet 7 Air suction grille 8 Corner decoration cover 9 Drain hose 10 Knockout hole Cassette height Minimal installation height Required installation space Model AA AB AC AD FCAG35/50/60/71BVEB 204 139 227 2,700 FCAG100/125/140BVEB 246 180 269 2,700 FCAHG71/100/125/140HVEB 288 180 311 2,700 FXFQ20/25/32/40/50/63BVEB 204 139 227 2,700 FXFQ80/100BVEB 246 180 269 2,700 FXFQ125BVEB 288 180 311 2,700 FXFA20/25/32/40/50/63A2VEB 204 139 227 2,500 FXFA80/100A2VEB 246 180 269 2,500 FXFA125A2VEB 288 180 311 2,500 ·300· or less Suspension position Respect the distances shown on the figure. Required installation space If a discharge outlet is closed up with the "sealing member" option kit, then the required installation space on that (closed up) side is ·500·mm instead of ·1,500·mm. DETAIL A ·2· places Opposite side DETAIL B ·2· places Opposite side DETAIL A ·2· places Opposite side ARROW VIEW C ARROW VIEW C DETAIL B ·2· places Opposite side See note ·5· Ceiling-mounted lighting See note ·6· Drain side Suspension bolt Installation box for adaptor PCB Only in case of ·FXFA· models Installation box for adaptor PCB Only in case of ·FXFA· models 4 - M8 or M10 Fixation holes Fixation holes Piping side See note ·3·. See note ·3·. Suspension position Adjustable Ceiling opening See note ·3·. Air fan Other unit ·4,000· or more ·2,000· or more ·1,500· or more ·1,500· or more ·200· or more ·200· or more ·1,500· or more ·1,500· or more ·1,500· or more Ceiling opening See note ·3·. Required installation space ·AD· or more 2D121658D NOTES 1. Location of nameplate The unit nameplate is located on the control box cover. The decoration panel nameplate is located on the piping-side panel frame, under the corner cover. 2. When installing optional accessories, refer to their respective documentation. 3. Make sure the distance between the ceiling and the cassette does not exceed 35 mm. The maximum ceiling opening is 910 mm. 4. When the conditions in the ceiling exceed 30°C ambient temperature and 80% relative humidity, or when fresh air is inducted into the ceiling, additional insulation is required (polyethylene foam, thickness ≥ 10 mm) 5. When installing a sensor kit, there will be a sensor on this location. For details, see the drawing of the sensor kit. Item Name 1 Liquid pipe connection port 2 Gas pipe connection port 3 Drain pipe connection 4 Power supply wiring intake 5 Transmission wiring intake hole 6 Air discharge outlet 7 Air suction grille 8 Corner decoration cover 9 Drain hose 10 Knockout hole 35 2 1 0 C 5 ARROW VIEW C 340 0 - 6 7 5 4 - 8 M10 1 2 4 3 950 9 5 0 8 7 6 AB 2 1 3 O75 10 DETAIL A 7 8 0 710 420 9 420 DETAIL B 121.5 350 9 5 5 4 . 5 5 4 . 5 81 100 100 85 9 6 . 5 DETAIL B 350 121.5 DETAIL A FCAG100/125/140BVEB FCAHG71/100/125/140HVEB FXFQ80/100/125BVEB FXFA80/100/125A2VEB 81 100 100 85 8 0 1 0 0 1 0 0 8 0 54.5 54.5 96.5 2 5 . 4 1 2 1 . 5 3 5 0 95 67 53 1 2 1 . 5 2 5 . 4 3 5 0 8 0 1 0 0 1 0 0 8 0 96.5 9 6 . 5 5 3 FCAG35/50/60/71BVEB FXFQ20/25/32/40/50/63BVEB FXFA20/25/32/40/50/63A2VEB FCAG100/125/140BVEB FCAHG71/100/125/140HVEB FXFQ80/100/125BVEB FXFA80/100/125A2VEB A B 860 910 8 6 0 - 9 1 0 35 10°10° 256 (*3) (*2) Opposite side Opposite side ·2· places ·2· places Opposite side ·2· places Opposite side ·2· places 6 7 7 Suspension bolt OR 330 280 9 0 2 3 0 A A 4 0 ( 9 0 ) 2 5 5 FCAG35/50/60/71BVEB FXFQ20/25/32/40/50/63BVEB FXFA20/25/32/40/50/63A2VEB 55 840 55 840 500· r mo e 0· ore 500 more 15 · o A C ARROW VIEW C FCAG35/50/60/71BVEB FXFQ20/25/32/40/50/63BVEB FXFA20/25/32/40/50/63A2VEB FCAG100/125/140BVEB FCAHG71/100/125/140HVEB FXFQ80/100/125BVEB FXFA80/100/125A2VEB D1216 58D ·300· or less Suspension position Respect the distances shown on the figure. Required installation space If a discharge outlet is closed up with the "sealing member" option kit, then the required installation space on that (closed up) side is ·500·mm instead of ·1,500·mm. (*1) Not applicable to recessed lighting. (*2) Required space for entering with vacuum cleaner tube. (*3) Make sure the decoration panel discharge outlet is not blocked. DETAIL B ·2· places Opposite side ARROW VIEW C ARROW VIEW C DETAIL B ·2· places Opposite side Installation direction See note ·5· Ceiling-mounted lighting Drain side Piping Dust opening Air suction grille Piping Suspension bolt 4 - M8 or M10 Piping side See note ·3·. See note ·3·. Suspension position Adjustable Ceiling opening See note ·3·. Air fan Other unit ·4,000· or more ·2,000· or more ·1,500· or more ·1,500· or more ·1,500· or more Ceiling opening See note ·3·. Required installation space ·AD· or more Installation box for adaptor PCB Only in case of ·FXFA· models Fixation holes Fixation holes Cassette height Minimal installation height Required installation space Model AA AB AC AD FCAG35/50/60/71BVEB 204 139 307 2,700 FCAG100/125/140BVEB 246 180 349 2,700 FCAHG71/100/125/140HVEB 288 180 391 2,700 FXFQ20/25/32/40/50/63BVEB 204 139 307 2,700 FXFQ80/100BVEB 246 180 349 2,700 FXFQ125BVEB 288 180 391 2,700 FXFA20/25/32/40/50/63A2VEB 204 139 307 2,500 FXFA80/100A2VEB 246 180 349 2,500 FXFA125A2VEB 288 180 391 2,500 350 150 110 2 25.4 25.4 100 100 100 100 80 80 80 80 ·200· or more ·1,500· or more Installation box for adaptor PCB Only in case of ·FXFA· models ·1,500· or more DETAIL A ·2· places Opposite side DETAIL A ·2· places Opposite side ·200· or more 190 Click here to view all FCAG-B technical drawings on my.daikin.eu Click here to view all FCAHG-H technical drawings on my.daikin.eu

RkJQdWJsaXNoZXIy MTE0MTkzMg==