VRV product catalogue

187 2 9 1 16 1000 845 2 9 1 6 2 F E D C B A 1 1 2 2 220 500 P100 X 5 = 280 500 P100 X 5 = 5 1 3 1030 135 135 12 13 3 5 6 7 8 9 9 1 11 4 9 9 14 305 1 6 2 2 4 4 305 1 154 122 2 4 4 14 Item Name Description 1 2 3 4 5 6 7 8 9 1 Suspension bracket Drain socket Inspection hole 11 VP20 (OD Ø26, ID Ø20) 12 Ø ·15.9· brazing connection Ø ·12.7· brazing connection Ø ·15.9· brazing connection Ø ·6.35· brazing connection Ø ·9.52· brazing connection Ø ·9.52· brazing connection M8~M10 13 14 Damper Duct connection kit Control box Diameter ·Ø160· Diameter ·Ø160· Outdoor unit suction gas pipe connection port Indoor unit gas pipe connection port Outdoor unit liquid pipe connection port Indoor unit liquid pipe connection port Duct connection Indoor unit gas pipe connection port Indoor unit gas pipe connection port Indoor unit liquid pipe connection port Ø ·22.2· brazing connection 40.5 A 9 8 1 3 4 346 122 1 3 0 2 3 0 SV6A14A 3D149359 2 9 1 16 1000 135 135 1 3 0 2 3 0 845 122 346 2 9 1 6 2 H G F E D C B A 120 700 P100 X 7 = 180 700 P100 X 7 = Item Name Description 1 2 3 4 5 6 7 8 9 1 Suspension bracket Drain socket Inspection hole 11 VP20 (OD Ø26, ID Ø20) 12 Ø ·15.9· brazing connection Ø ·12.7· brazing connection Ø ·15.9· brazing connection Ø ·6.35· brazing connection Ø ·9.52· brazing connection Ø ·9.52· brazing connection M8~M10 1 1 2 2 14 13 14 Damper Duct connection kit 12 13 3 5 6 7 8 9 9 10 11 4 5 1 3 1030 9 9 Control box Diameter ·Ø160· Diameter ·Ø160· 2 4 4 305 154 197 305 1 6 2 Outdoor unit suction gas pipe connection port Indoor unit gas pipe connection port Outdoor unit liquid pipe connection port Indoor unit liquid pipe connection port Duct connection Indoor unit gas pipe connection port Indoor unit gas pipe connection port Indoor unit liquid pipe connection port Ø ·22.2· brazing connection 122 2 4 4 14 40 5 A 9 8 1 3 4 SV8A14A 3D149360 Option kit EKBSDCK Option kit EKBSDCK Detail ·A· Detail ·A· 3D149359 3D149360 SV6A14A SV8A14A Item Name Description 1 Outdoor unit suction gas pipe connection port Ø ·22.2· brazing connection 2 Outdoor unit liquid pipe connection port Ø ·15.9· brazing connection 3 Indoor unit gas pipe connection port Ø ·9.52· brazing connection 4 Indoor unit gas pipe connection port Ø ·12.7· brazing connection 5 Indoor unit gas pipe connection port Ø ·15.9· brazing connection 6 Indoor unit liquid pipe connection port Ø ·6.35· brazing connection 7 Indoor unit liquid pipe connection port Ø ·9.52· brazing connection 8 Control box 9 Suspension bracket M8~M10 10 Drain socket VP20 (OD Ø26, ID Ø20) 11 Inspection hole 12 Duct connection Diameter ·Ø160· 13 Damper 14 Duct connection kit Diameter ·Ø160· Item Name Description 1 Outdoor unit suction gas pipe connection port Ø ·22.2· brazing connection 2 Outdoor unit liquid pipe connection port Ø ·15.9· brazing connection 3 Indoor unit gas pipe connection port Ø ·9.52· brazing connection 4 Indoor unit gas pipe connection port Ø ·12.7· brazing connection 5 Indoor unit gas pipe connection port Ø ·15.9· brazing connection 6 Indoor unit liquid pipe connection port Ø ·6.35· brazing connection 7 Indoor unit liquid pipe connection port Ø ·9.52· brazing connection 8 Control box 9 Suspension bracket M8~M10 10 Drain socket VP20 (OD Ø26, ID Ø20) 11 Inspection hole 12 Duct connection Diameter ·Ø160· 13 Damper 14 Duct connection kit Diameter ·Ø160· Detailed technical drawings Click here to view all SV-A technical drawings on my.daikin.eu

RkJQdWJsaXNoZXIy MTE0MTkzMg==