03_ECPEN27-500_Heating

105 BRC1HHDK(7) R-290 up to up to 75°C LWT 75°C at -15°C At 35°C average climate At 55°C average climate +++ D A+++ + F A+ Whisper quiet Onecta app Guaranteed operation down to -28°C EPSK06-14AV3/W1 EPVX10-14A4V/9W EPVX10-14A4V/9W + EPSK06-14AV3/W1 Daikin Altherma 4 H F Floor standing air‑to‑water heat pump for heating, cooling and hot water J New intuitive MMI 5” touchscreen for better user experience J Inclusion of all hydraulic components means no third party components are required J PCB board and hydraulic components are located in the front for easy access J A combined stainless steel domestic hot water tank of 180 or 230L and heat pump for easy installation J Integrated back-up heater of 4.5 or 9kW EPSK06-10AV3 EPSK08-10AW1 EPSK12-14AW1 011-1W0929 011-1W0930 011-1W0931 011-1W0933 011-1W0934 011-1W1097 EPVX10A4V EPVX10A9W EPVX14A4V EPVX14A9W Efficiency data EPVX + EPSK 10S18/S23A4V/9W + 06AV3 10S18/S23A4V/9W + 08AV3 10S18/S23A4V/9W + 10AV3 10S18/S23A4V/9W + 08AW1 10S18/S23A4V/9W + 10AW1 14S18/S23A4V/9W + 12AW1 14S18/S23A4V/9W + 14AW1 Heating capacity/ Power input A -7°C/W 35°C Max. kW 6.23/1.84 7.83/2.40 9.10/3.20 7.83/2.40 9.10/3.20 10.43/3.34 13.73/4.91 A -7°C/W 55°C Max. kW 6.63/2.61 7.86/3.06 9.48/4.07 7.86/3.06 9.10/3.20 12.14/5.00 13.3/5.66 A -7°C/W 60°C Max. kW 5.53/2.29 7.76/3.37 9.36/4.51 7.76/3.37 9.36/4.51 11.37/5.28 13.12/6.10 A -7°C/W 65°C Max. kW 5.18/2.51 6.69/3.55 7.14/3.99 6.69/3.55 7.14/3.99 11.22/5.66 12.94/6.53 A -2°C/W 35°C Max. kW 5.65/1.52 6.96/2.08 7.72/2.59 6.96/2.08 7.72/2.59 9.551/3.13 12.87/4.34 A -2°C/W 70°C Max. kW 5.46/2.60 6.76/3.35 7.43/4.16 6.76/3.35 7.43/4.16 9.588/5.16 9.962/5.54 A 2°C/W 35°C Max. kW 4.86/1.24 5.91/1.69 6.91/2.17 5.91/1.69 6.91/2.17 8.971/2.63 11.25/3.23 A 7°C/W 35°C Max. kW 5.73/1.07 7.48/1.44 9.70/2.11 7.48/1.44 9.70/2.11 12.27/2.29 10.74/2.57 A 7°C/W 45°C Max. kW 5.82/1.30 7.61/1.75 9.87/2.56 7.61/1.75 9.87/2.56 12.08/3.02 15.16/3.8 A 7°C/W 55°C Max. kW 5.92/1.53 7.74/2.05 10.04/3.01 7.74/2.05 10.04/3.01 12.16/3.55 15.26/4.45 Heating capacity Nom. kW 5.81 7.62 8.11 7.62 8.11 10.2 Power input Heating kW 1.12 1.52 1.64 1.52 1.64 1.86 Space heating Average climate water outlet 55°C General SCOP 3.91 3.97 4.02 3.94 3.99 4.04 3.84 ηs (Seasonal heat. eff.) % 153 156 158 155 157 159 150 Seasonal space heating eff. class A+++ (Range A+++ to D) Prated at -10°C kW 6.5 7.5 8.5 7.5 8.5 10.5 14 Average climate water outlet 35°C General SCOP 5.12 5.15 5.14 4.96 ηs (Seasonal heat. eff.) % 202 203 202 203 195 Seasonal space heating eff. class A+++ (Range A+++ to D) Prated at -10°C kW 6.5 7.5 8.5 7.5 8.5 10 12 Domestic hot water heating General Declared load profile L Average climate COPdhw 2.93 2.91 3.03 ηwh (water heating efficiency) % 117 116 121 Water heating energy efficiency class A+ (Range A+ to F) Indoor Unit EPVX 10S18/S23A4V/9W 10S18/S23A4V/9W 14S18/S23A4V/9W Casing Material Precoated galvanized steel + plastic Tank Insulation Material Polyurethane foam Heat loss kWh/24h 1.20/1.40 Dimensions Unit HeightxWidthxDepth mm 1,650x595x625/1,850x595x625 Weight Unit kg 94.0/111 Tank Water volume l 180/230 Maximum water temperature °C 65 Maximum water pressure bar 10 Corrosion protection Pickling Operation range Indoor installation Ambient Min.~Max. °CDB 5~35(4) Heating Water side Min.~Max. °C 15~70 15~75 Domestic hot water Water side Min.~Max. °C 10~75 Sound power level Nom. dBA 45.0(1) Sound pressure level Nom. dBA 31.0(2) Water circuit Piping connections diameter inch G 1" (female) Water circuit - DHW side Piping connections Cold water in/Hot water out inch G 3/4" FEMALE Pump Type Grundfos UPM4XL LIN 25-90 Grundfos UPM10XL LIN 25-125 Outdoor Unit EPSK 06AV3 08AV3 10AV3 08AW1 10AW1 12AW1 14AW1 Dimensions Unit HeightxWidthxDepth mm 1,123x1,330x604 Weight Unit kg 174 178 191 Compressor Quantity / Type 1 / Hermetically sealed scroll compressor Operation range Heating/Cooling Min.~Max. °CDB -28~25/10~43 Domestic hot water Min.~Max. °CDB -28~40 Refrigerant Type/GWP/Control R-290/3/Expansion valve Charge kg/tCO₂eq 1/0.003 Sound power level Heating/Cooling Nom./Nom. dBA 45(5)/52.2(6) 45(5)/53(6) 47(5)/53.2(6) 45(5)/53(6) 47(5)/53.2(6) 52(5)/62(6) 52(5)/63(6) Sound pressure level Heating/Cooling Nom./Nom. dBA 32.6(5)/36.9(6) 32.4(5)/37.2(6) 32.8(5)/37.3(6) 32.4(5)/37.2(6) 32.8(5)/37.3(6) 38(5)/47(6) 38(5)/48(6) Night quiet mode Heating/Cooling dBA 29.5(5)/30.8(6) 30(5)/30.8(6) 33(5)/30.8(6) 30(5)/30.8(6) 33(5)/30.8(6) 38(5)/41(6) Piping connections Piping length OU - IU Max. m 20(7)/30(8) 20(7)/50(8) Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3~/50/400 Current Recommended fuses A 25 16 (1)Measured with a pressure drop of 10kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. | (2)Value measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. The sound pressure level mentioned is measured with a pressure drop of 10kPa in the heating system at an operating condition of leaving water temperature 47-55°C in a room with an ambient temperature of 20°C. DB/WB 7°C/6°C | (3)Refer to operation range of the unit. | (4)Depends on operation mode, refer to installation manual. | (5)Measured at LWC 47-55°C; Ta DB/WB 7°C/6°C. | (6)Measured at LWC 12-7°C; Ta 35°C. | (7)1 1/4” field piping | (8)1 1/2” field piping

RkJQdWJsaXNoZXIy MTE0MTkzMg==