03_ECPEN27-500_Heating

Heating All-in-one comfort for residential applications 2027 NEW

78 The X Series combines air‑to‑air and air‑to‑water technology in one flexible solution for residential projects. One outdoor unit connects up to four air‑to‑air indoor units and supports underfloor heating, domestic hot water and low-temperature radiators. Suitable for new-build homes up to 150m², it helps installers deliver year-round comfort with less system complexity. X Series Mixed technology in one heat pump. daikin.eu To heat floors and water. To warm and cool air.

79 4 steps to decarbonising residential heat 80 Service & Solutions 82 Stand By Me, Certified Partner 84 Six reasons to choose a heat pump 86 Individual solutions 92 Heat pumps 92 J Indoor units 94 J Daikin Altherma 4 H 98 - Daikin Altherma 4 H F 104 - Daikin Altherma 4 H ECH2O 106 - Daikin Altherma 4 H W 110 J Daikin Altherma 3 H MT/HT 116 - Daikin Altherma 3 H MT/HT F 118 - Daikin Altherma 3 H MT/HT ECH2O 121 - Daikin Altherma 3 H MT/HT W 125 J Daikin Altherma 3 R MT 130 - Daikin Altherma 3 R MT F 132 - Daikin Altherma 3 R MT ECH2O 135 - Daikin Altherma 3 R MT W 139 J Daikin Altherma 3 R (ERLA-D series, 11-14-16kW) 144 - Daikin Altherma 3 R F 146 - Daikin Altherma 3 R ECH2O 150 - Daikin Altherma 3 R W 154 J Daikin Altherma 3 R (ERGA-E series, 4-6-8kW) 158 - Daikin Altherma 3 R F 160 - Daikin Altherma 3 R ECH2O 163 - Daikin Altherma 3 R W 168 J Daikin Altherma 3 M 172 - Daikin Altherma 3 M (4-6-8kW) 174 - Daikin Altherma 3 M (9-11-14-16kW) 176 J Daikin Altherma 4 M HW 180 J Daikin Altherma Ground source heat pump 186 - Daikin Altherma 3 GEO 186 J Daikin Altherma Hybrid heat pump 190 - Daikin Altherma H Hybrid 190 Boilers 199 J Gas condensing boilers 200 - Daikin Altherma 3 C Gas (D2C/TND*) 201 - Daikin Altherma C Gas W 206 J Flue-gas evacuation system 208 Collective solutions 211 Decentralised solutions 214 Centralised solutions 215 Water loop 216 J Daikin Altherma 3 WS 216 Peripherals 224 Tanks 227 J Thermal stores and tanks 228 Controllers 233 J Wired remote controller 234 J Daikin Home Controls 236 J HomeHub 238 J DCS Residential 240 J Onecta App 242 Heating & cooling emitters 245 J Daikin Altherma UFH 246 J Daikin Altherma HPC floor standing 252 J Daikin Altherma HPC wall mounted 254 J Daikin Altherma HPC concealed 255 Solar heating systems 261 J Solar panels for pressurised use and Drain-back system 268 J Solar panel - pressurised option list 270 J Solar panels - drain-back option list 272 J Solar collector 275 J Pump station 275 Heating

80 4 Steps to decarbonising residential heat Strengthened new build rules Increase replacement rate 2020 2030 40% One of the biggest challenges in residential heating is increasing the use of energy sources that can be replenished naturally. Many homes are still heated with older systems that rely on fuels such as coal and oil. Replacing outdated heating systems with modern alternatives can help improve heating efficiency and reduce dependence on these energy sources. The challenge involved in tackling this is made all the more clear by The European Green Deal, which is a set of policy initiatives by the European Commission with the key aim of making Europe climate neutral in 2050. All European member states have already put measures in place to ensure that new build houses and apartments have a better carbon performance by making an improved building envelope and by using renewable energy mandatory. According to industry reports and market analysis, heat pumps are estimated to have up to 50% market share in new single-family houses. A considerable additional benefit of hydronic heat pumps is the ability to use it to cool as well heat, which is increasingly becoming a consumer requirement. This is partly due to the climate change effect, but also because of the higher insulation level built houses. Today’s replacement rate is, on average, 1% of the total number of heating systems installed per year and meeting the minimum target would require that replacement ratio to double within the coming 10 years. Substituting heating devices with more efficient ones will constitute a move towards reducing CO2 emission. The challenge however is to motivate EU citizens to choose renewable heating more often, thereby convincing those in the replacement market that heat pumps are an efficient, cost-effective and established solution. European Green Deal

81 End fossil fuel incentives Renewable heating standard in replacement 100% 2050 Policy makers could avoid incentives for fossil fuels. Currently, direct or indirect incentives benefit oil or gasbased boilers, due to different taxation of heat pumps compared with boilers for instance. While doing this, it is important to note that in many member states, the current gap between electricity and gas prices can make a heat pump less economically attractive for EU citizens compared to traditional heating systems. However, government incentives and future energy price trends could change this dynamic. In the short term, government incentives can help accelerate the transition to carbon-neutral heating and make heat pumps accessible to all Europeans, but in the longer term more balanced energy prices and a correct indication of the energy and carbon performance of a building need to support the end user motivations to invest in heat pump technology. At Daikin, we believe heat pump systems have to become the standard when replacing heating systems. It is a fact that heat pumps are increasingly capable of high efficiencies, even at lower outdoor temperatures. The hydronic heat pump technology has developed quickly in recent years, making it fit for any type of residential building in Europe whether it is for the new build market or the replacement market. The future At Daikin we’re excited and passionate about taking on the changing environment and playing a key role in bringing this innovative technology into people’s homes while ensuring all stakeholders, such as installers and architects, are on board. We can do our bit as well by making installation as simple as possible through great design. Europe has the technology, the expertise and the investments to expand the heat pump market further. From single family to multi-family homes, from small to large commercial buildings and industrial plants, heat pumps today are ready to go mainstream. All the signs are indicating that we need to act now! Heat pumps start to play a crucial role in decarbonizing Europe, and in certain areas there has already been an impressive uptake. For example, heat pumps are the default heating system in Sweden and enjoy 50% of the market share in new builds in some European countries. However, in the whole of Europe, renewable heating via heat pumps represents only 10% of all heating systems installed annually. This contrasts sharply with the EU Commission’s ambitious target by 2030: 40% penetration of renewables in heating and cooling. At Daikin, we see the solution will be to take 4 steps to decarbonizing residential heat, in order to achieve the EU Commission’s targets by 2030.

82 It’s time to relax. With your customer’s new Daikin installation and Stand By Me service programme, you can rest assured they are benefiting from the best comfort, energy efficiency, usability and service available on the market. Daikin’s service programme significantly reduces customer concerns through extended warranties, quick follow-up, and additional support. Service & solutions a journey to customer satisfaction Discover in detail the Daikin Metroline Have a detailed look at each stop to see how our tools can facilitate your journey with Daikin. Scan the QR code or go to http://metro.standbyme.daikin.eu for the tool Heating Solutions Navigator Stand By Me Residential Solutions Navigator Daikin e-Care Daikin ONECTA App Do the radiator test Simplified heat load Room by Room Heat Load Calculation Radiator selection Heat pump Convector End user quotation Piping & Wiring Thermal solar calculation tool Underfloor heating Pipe sizing Ventilation Literature Economic Viability Study e-Configuration tool Installation registration e-Configuration tool Hydrobalancing tool Installation registration Commissioning tool Maintenance Maintenance guide e-Doctor Installation monitoring Spareparts ordering Repair Installation registration Warranty extension Maintenance Repair Remote control e-Configuration tool Installation registration Installation monitoring Warranty extension Maintenance Repair Residential Solutions Navigator 3 2 4 5 HSNPRO 3 2 4 5 HSNPRO 3 2 4 5 HSNPRO 3 2 4 5 HSNPRO Stand By Me Manage your installation database and offer comfort and service to your customer Web portal Professionals 3 2 4 5 HSNPRO Daikin e-Care Access to registration, commissioning, configuration and trouble shooting Mobile app Professionals Residential Solutions Navigator Provides you with leads that come with more in-depth details Web portal Consumer First contact with customer Customers explore solutions 3 2 4 5 HSNPRO Heating Solutions Navigator Provide the best fit solution for your customers' homes Web portal Professionals 3 2 4 5 HSNPRO 1 Onecta app End-user app to control the residential unit Consumer Mobile app 3 2 4 5 HSNPRO Ultimate customer satisfaction Daikin Cloud Service Residential Consumer Mobile app 3 2 4 5 HSNPRO

83 3 2 4 5 HSNPRO Scan the QR code to download Daikin e-Care now 3 2 4 5 HSNPRO HSNPRO 3 2 4 5 HSNPRO Discover the new features We keep investing in the support towards our installers. With your Daikin account, you have access to Stand By Me and the Heating Solutions Navigator online. Use the same account to access the Daikin e-Care app. The tools offer now new features, check it out! Heating Solutions Navigator Newest function: J Multi-Family Home J Integration Multi Selection Software J New product range: X Series Stand By Me Newest functions: J Trainings for professionals (SBM CP Program) J Direct Service offering from professionals to end-users via SBM (Daikin à la Carte) Daikin Cloud Service Residential Newest functions: J Remote monitoring of Daikin Altherma 4 (extended features) J Remote monitoring of Daikin Altherma 3 (limited features) Daikin e-Care Newest function: J Guided commissioning via online check list J Support for trouble shooting J Direct access to installation manuals J Digital Key for Daikin Altherma 4 Residential Solutions Navigator J Detailed Multi(+) calculation Guided commissioning via online checklist e-Commissioning is the latest tool released in the e-Care app, aiming to improve the quality and reliability of Daikin installations. It is a step-by-step checklist that assists service partners during the commissioning of the unit. J Product-specific and country-specific checklist, to ensure maximum flexibility of use and compliance with local requirement J Get instant feedback if there are problems with the checklist (screen will display an error message) J Generated PDF report available at all times via the e-Care app or via the SBM professional portal J Generated commissioning documents automatically sent to the end user in case of successful commissioning J Possibility to save a draft of the checklist at any time J Offline use J Possibility to upload pictures of the installation site J Possibility to add end user and professional signatures J Available for Daikin Altherma units e-Care installation details after Registration Example of the correct answer Example of the incorrect answer NEW 3 2 4 5 HSNPRO

84 Stand By Me Certified Partner Purpose of the programme The programme is designed to support you and your customers throughout every stage of the product lifecycle, from installation to after-sales service.Through dedicated training and ongoing support from Daikin professionals, you can further develop your skills and expand your opportunities in the heating market, backed by the reputation of a globally recognised brand. Benefits Stand out with specialised Daikin expertise and gain access to the knowledge and tools that support professional installation and service delivery. Expand your product knowledge through advanced training programmes and strengthen your market presence as a Stand By Me Certified Partner. Show your customers your commitment to professional service with recognised Daikin certification and ongoing support throughout the lifecycle of Daikin Altherma systems.. Benefit from access to branded workwear, personal protective equipment and professional accessories.

85 How to become a Stand By Me Certified Partner Take the next step towards becoming a Stand By Me Certified Partner. Depending on your existing F-gas certification, you can follow the training path that matches your qualifications: J Track 1: for installers certified under EU 2024/2215 J Track 2: for installers certified under EU 2015/2067 Track 1: for installers certified under EU 2024/2215 To perform repair Safety Training Storage – transportation - installation 30min. Online L1 Safety Training R-290 product specific safety 30min. Online L3S These trainings are necessary to perform commissioning, and repair activities on R-290 products that belong to the Daikin Altherma 4 series. Track 2: for installers certified under EU 2015/2067 Safety Training Storage – transportation - installation 30min. Online L1 Safety Training or F-Gas module on R-290 Repair - disposal 1 day Classroom L2B Safety Training R-290 product specific safety 30min. Online L3S These trainings are necessary to perform commissioning, and repair activities on R-290 products that belong to the Daikin Altherma 4 series. Optional training: To perform maintenance/repair Product Training F-gas license necessary to start this training 1 day Classroom L3 This training provides more information on maintenance and repair activities on R-290 products for contracts on Stand By Me platform that belong to the Daikin Altherma 4 series. Update 2026 For commissioning and maintenance, please check with your local Daikin contact if a specific training is needed.

86 reasons to choose a heat pump 6 New built or full renovation New built house Replace the existing heating system (gas boiler with radiators) Optimise existing heating system (gas boiler with radiators) Optimise existing heating system (multiple rooms application) New built or replace electric heaters indoor unit outdoor unit outdoor unit indoor units water tank Daikin Altherma LT / HT / GEO Daikin Altherma LT / HT / Hybrid / GEO Daikin Altherma Add-On (Monobloc heat pump) Air-to-air heat pumps Multi Pair Hydronic heat pumps outdoor unit indoor units water tank space heating Multi+ X-Series Optimise existing heating system (one room application) Mixed technology outdoor unit indoor units

87 1 A heat pump increases the value of your property The installation of heat pumps can enhance the Energy Performance Certificate (EPC) ratings of buildings in Europe; improvements may vary but are often observed to be significant. This improvement can lead to energy savings and increased comfort, potentially enhancing the environmental profile of your property. 2 Projections of savings on energy costs by heat pumps The installation of a heat pump to substitute a gas boiler is expected to generate energy savings over 10 years. Energy savings are likely to grow at a steady pace over the years. Daikin Europe conducted simulations to forecast energy prices, considering factors such as historical prices, the European Emission Trading System (ETS), and future carbon taxation. 3 Incentive schemes on heat pump technology Although heat pumps may require a higher initial investment than traditional heating systems, they are often eligible for government incentives and premiums. To contrast climate change, many governments are phasing out gas and oil boilers and promoting solutions like heat pumps. Historically, convincing homeowners to switch to heat pumps has been challenging, but rising gas prices and the availability of subsidies across Europe are increasing interest and acceptance.These subsidies can make heat pumps more competitive, accelerating the transition to sustainable heating solutions. 4 Seamless comfort all-year-round Our systems provide heating, cooling, and domestic hot water from a single, efficient source. By adapting the home’s specific needs, they ensure optimal comfort in every season. This intelligent design reduces energy consumption while maintaining consistent performance. The result is a convenient home comfort solution that simplifies daily living. 5 Environmental impact of heat pumps Heat pumps are vital for achieving the EU's decarbonization goals. A case study shows that Daikin heat pumps can be 2 to 24 times less carbon-intensive than gas boilers, leading to annual CO2 savings of 0.2 to 2 tons, depending on the electricity grid. The EU Green Deal aims to reduce greenhouse gas emissions by 55% by 2050. With buildings responsible for 40% of energy use and 36% of emissions, heat pumps provide a more efficient solution. Benefits include high efficiency and reduced fossil fuel dependency. According to our analysis based on current trends, this could lead to a reduction of 21 billion cubic meters in gas demand for heating by 2030. 6 Synergies among the usage of heat pumps with solar panel (PV) systems A heat pump can enhance the self-consumption rate of a residential photovoltaic (PV) installation by about 10%, yielding annual financial benefits of €80 to €120, depending on energy prices. This is based on a Daikin case study of a 5kWp PV system and a heat pump with a 250 liter tank in Belgium. Combining heat pumps with PV panels allows households to use free solar electricity for heating and hot water, reducing reliance on gas. As feed-in tariffs decrease across Europe, maximizing self-consumption becomes increasingly important. The heat pump can utilize excess solar energy to heat domestic hot water, effectively acting as an "energy battery" by storing energy for later use.

88 By Summer ‘27, a small capacity hydrosplit outdoor unit will be launched from 4 to 7kW J Efficiencies up to A+++ in heating (35°C) J Compact outdoor unit combinable with a wall mounted, integrated floor standing or ECH20 indoor unit Daikin Altherma 4 expands its range in 2027

89 Hydronic heat pumps J Indoor units 94 J Daikin Altherma 4 H 98 - Daikin Altherma 4 H F 104 - Daikin Altherma 4 H ECH2O 106 - Daikin Altherma 4 H W 110 J Daikin Altherma 3 H MT/HT 116 - Daikin Altherma 3 H MT/HT F 118 - Daikin Altherma 3 H MT/HT ECH2O 121 - Daikin Altherma 3 H MT/HT W 125 J Daikin Altherma 3 R MT 130 - Daikin Altherma 3 R MT F 132 - Daikin Altherma 3 R MT ECH2O 135 - Daikin Altherma 3 R MT W 139 J Daikin Altherma 3 R (ERLA-D series, 11-14-16kW) 144 - Daikin Altherma 3 R F 146 - Daikin Altherma 3 R ECH2O 150 - Daikin Altherma 3 R W 154 J Daikin Altherma 3 R (ERGA-E series, 4-6-8kW) 158 - Daikin Altherma 3 R F 160 - Daikin Altherma 3 R ECH2O 163 - Daikin Altherma 3 R W 168 J Daikin Altherma 3 M 172 - Daikin Altherma 3 M (4-6-8kW) 174 - Daikin Altherma 3 M (9-11-14-16kW) 176 J Daikin Altherma M HW 180 J Daikin Altherma Ground source heat pump 186 - Daikin Altherma 3 GEO 186 J Daikin Altherma Hybrid heat pump 190 - Daikin Altherma H Hybrid 190

90 Daikin Altherma heat pump portfolio At Daikin, heat pumps are at the heart of everything we do. Our residential solutions include a broad portfolio— from air‑to‑water and hybrid systems to ground source heat pumps. Designed for year-round comfort, Daikin heat pumps deliver efficient heating, cooling, and domestic hot water tailored to every home. Outdoor unit Material name 03 04 05 06 07 08 09 10 11 12 14 16 18 Air‑to‑water heat pumps Daikin Altherma 4 H EPSKS-AV3 70°C R-290 • • • EPSK-AV3/W1 75°C R-290 • • • • • Daikin Altherma 3 H HT EPRA-DV37/W17 70°C • • • Daikin Altherma 3 H MT EPRA-EV3/W1 65°C • • • Daikin Altherma 3 R MT ERRA-EV37/EW17 65°C • • • Daikin Altherma 3 R ERGA-EV(A)/(H)(7) 65°C • • • Daikin Altherma 3 R ERLA-DV38/W18 60°C • • • Daikin Altherma 3 M EBLA-E • • • EDLA-E 65°C • • • Daikin Altherma 3 M EBLA-D(7) • • • • EDLA-D 60°C • • • • Hybrid heat pump Daikin Altherma H Hybrid EJHA-AV3 65°C • Ground source heat pump Daikin Altherma 3 GEO 65°C Daikin Altherma 3 WS 65°C Gas condensingboiler Daikin Altherma C Gas W

91 Indoor unit Material name 03 04 05 06 07 08 09 10 11 12 14 16 18 22 24 28 32 33 35 F EPVX-A4V/9W • ECH2O EPSX(B)-P-A • W EPBX-AV4 • F EPVX-S-A4V/9W • • ECH2O EPSX(B)-P-A • • W EPBX-AV4/9W • • F ETVH/X/Z-E7 • ECH2O ETSH(B)/X(B)-E7 • W ETBH/X-E7 • F ETVH/X/Z-E • ECH2O ETSH(B)/X(B) P-E • W ETBH/X-E • F ELVH/X/Z-E • ECH2O ELSH/X(B)-E • W ELBH/X-E • F EHVH/X/Z-E • • ECH2O EHSH(B)/X(B)-P-E • • W EHBH/X-E • • F EBVH/X/Z-D • • ECH2O EBSH(B)/X(B)-D • • W EBBH/EBBX-D • • Boiler EHY2KOMBA A • • EGSAH/X-D9W • R-32 • EWSA-D • R-32 Boiler D2CND-A1A/A4A • • • D2TND-A4A • • • • • D2CNL-A1A • EHOBG-A • • EKOMBG-A / EKOMB-AH • • • F - Integrated floor standing W - Wall mounted ECH2O - HPSU X - Reversible H - Heating only

92 One solution, multiple combinations Daikin Altherma product ranges can be combined with three different indoor units to connect to the outdoor unit, offering specific features to ensure heating, cooling and domestic hot water in your home. Daikin indoor units can be installed in different places, garage, basement, utility room or even a kitchen while still blending in with the indoor design. The units have also been designed to ease the work of the installer and therefore contribute to your peace of mind! Integrated ECH2O DHW tank model Integrated floor standing model Wall mounted model Advanced user interface The Daikin Eye The intuitive Daikin eye shows you in real time the status of your system. Blue is perfect! Should the eye turn red, an error has occured. Quick to configure Log in and you’ll be able to completely configure the unit via the new interface in less than 10 steps. You can even check if the unit is ready for use by running test cycles! Easy operation Work super-fast with the interface. It’s super easy to use with an intuitive interface. Beautiful design The interface was especially designed to be very intuitive. The high contrasted colour screen delivers stunning and practical visuals that really help you as installer or service engineer.

93 Choose from the Daikin "Three Pluses" the functionality that best fits your customer’s needs. The indoor units come in 3 versions: heating only, reversible and bizone, giving you the opportunity to tailor your Daikin heating system. Reversible model If cooling is needed, all three indoor units have dedicated reversible models. Reversible means that the system can invert its way of working and provide cooling instead of heating. The cooling function requires a underfloor piping system or fan coil units. Bizone model Only the integrated floor standing model has a dedicated bizone model: you can choose two independent zones with different emitters that need a different temperature level in different rooms (for example: underfloor heating system in the living room and radiators in the bedrooms upstairs). Discover more on page 242 Control with Onecta app Indoor units are applicable for: Daikin Altherma 3 R (ERGA-E series, 4-6-8kW) Daikin Altherma 3 R (ERLA-D series, 11-14-16kW) Daikin Altherma 3 H MT/HT Daikin Altherma 3 R MT Daikin Altherma 4 H (with 5" touchscreen) NEW Zone 1 / Night: Bedrooms Equipped with radiators. Programmed to work in the evening and in the morning. Zone 2 / Day: Living rooms Equipped with fan coils, and/or underfloor heating; works on demand. Daikin Altherma HPC (heat pump convectors) are hydronic emitters that can provide cooling or heating. They can be combined and are a perfect fit with underfloor systems. Your underfloor piping system is designed to receive mid-temperature water to heat your home, but when the summer comes, the pipes can also receive colder water to refresh your environment. MT 65°C* MT 70°C* 35°C 45°C Heating only model Some series offer a dedicated heating only unit for homes needing just heating and domestic hot water. In others, cooling can be disabled via installer settings. Bizone model: If your home has emitters needing different water temperatures, use a bizone kit or dedicated bizone model to manage both zones. Intelligent storage management J The unit is ‘Smart Grid’ ready to take advantage of low energy tariffs and efficiently store thermal energy for space heating and domestic hot water J Continuous heating during defrost mode and use of stored heat for space heating (ECH2O 500l tank only) J Electronic management of both heat pump and domestic hot water maximises energy efficiency, as well as convenient heating and domestic hot water J Uses more renewable energy with solar connection SG Ready Smart Heat Pumps

94 Reduces the installation footprint J Compared to the traditional split version for a wall mounted indoor unit and a separate domestic hot water tank, the integrated indoor unit greatly reduces the installation space required. J For installation projects, almost no side clearance is necessary as the piping is located at the top of the unit. J With unit height of 1.65m for an 180 L tank and 1.85m for a 230 L tank, the required installation height is less than 2m. J The compactness is emphasised by its sleek design and modern look, easy blending in with other household appliances. All in one system to save installation space and time J A combined stainless steel domestic hot water tank of 180 or 230 L and heat pump ensures a faster installation compared to traditional systems. J Inclusion of all hydraulic components means no third party components are required. J PCB board and hydraulic components are located in the front for easy access J Integrated back-up heater choice of 4, 6 or 9kW models are available J Dedicated bi-zone models providing different water temperatures to zones with different needs. For example, 35°C for underfloor heating and 45°C for radiators in the same house. Indoor units Floor standing unit Why choose Daikin Altherma floor standing unit with integrated domestic hot water tank? The Daikin Altherma floor standing unit is the ideal system to deliver heating, domestic hot water and cooling for renovation or new built.

95 Floor standing unit with integrated ECH2O tank The Daikin Altherma with integrated ECH2O tank is renowned for its ability to maximise renewable energy sources to provide the ultimate comfort in heating, domestic hot water and cooling. Innovative and highquality tank J Lightweight plastic tank J No corrosion, anode, scale or lime deposits J Contains impact resistant polypropylene inner and outer walls filled with high-grade insulation foam to reduce heat losses to a minimum Combinable with other heat sources J The bivalent option allows heat from other sources such as oil, gas or pellet-fired boilers to be stored in the solar system, further lowering energy consumption ECH2O thermal store range: additional hot water comfort Combine your indoor unit with a thermal store to achieve the ultimate comfort at home. J Fresh water principle: receive domestic hot water on demand while eliminating the risk of contamination and sedimentation J Optimal domestic hot water performance: the low temperature evolution enables high tapping performance J Fit for the future: possibility to integrate with renewable solar energy and other heat sources, e.g. fireplace J Lightweight and robust build of the unit combined with the cascade principle offers flexible installation options Built for small and large homes, customers can choose between a pressureless and a pressurised thermal solar system. Utilisation of solar energy for domestic hot water and central heating Heat pump (environmental heat) Auxiliary energy (electricity) 2,500 2,000 1,500 1,000 500 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec kWh Monthly energy consumption of an average detached house

96 High flexibility for installation J Inclusion of all hydraulic components means no third party components are required J PCB board and hydraulic components are located in the front for easy access J Compact dimensions allows for small installation space, as almost no side clearances are required J The unit’s sleek design blends in with other household appliances J Combine with a stainless steel or ECH 2O thermal store Flexibility in providing domestic hot water connection Whether you only need hot water or want to combine it with solar systems, our solutions are designed for high levels of comfort, energy efficiency, and reliability. J ECH 2O thermal store with fresh water principle: domestic hot water on demand while eliminating the risk of contamination and sedimentation. Possible to integrate with renewable thermal solar energy. J Stainless steel tanks: if installation height is limited, a separate stainless steel tank provides the required installation flexibility thanks to the different sizes available. Flexibility in providing space heating The wall mounted unit is the perfect choice in case the end user is looking for space heating or cooling while domestic hot water is provided by another system. Wall mounted unit Why choose Daikin wall mounted unit? The Daikin Altherma wall mounted unit offers heating and cooling with high flexibility for a quick and easy installation, with an optional connection to deliver domestic hot water.

97

98 Daikin Altherma 4 H is an extremely efficient high temperature heat pump made to cover the needs of existing houses with traditional heating emitters. Daikin Altherma 4 H New high temperature air‑to‑water heat pump, perfect for any house modernization Mounting stand and cover To make your outdoor unit blend in even more with your garden or terrace, a mounting stand and cover will make the look complete. Wind cover To protect the outdoor unit from severe wind, an optional wind cover can be installed for reliable operation: Integrated front grille Front installation Rear installation

99 Reliable cold climate operation With best-in-class heating capacity, Daikin Altherma 4 H delivers up to 13kW at -7/55°C (class 14 unit), ensuring warmth when it matters most. Daikin Altherma 4 operates down to -28°C even in the harshest conditions, providing consistent comfort no matter the weather. Good replacement solution Daikin Altherma 4 H is perfect for replacing fossil fuel boilers, as it fits seamlessly with existing radiators, delivering outstanding leaving water temperatures (LWT) of 70-75°C even at -15°C. Applicable for single family houses Daikin Altherma 4 H is perfectly suited for single-family homes, with an outdoor unit that can be conveniently installed on the roof or in the garden. Technology designed to boost performance to the next level Engineered with in-house developed and produced key components, such as the compressor and the micro-channel heat exchanger, creates a synergy that ensures unmatched performance in all weather conditions. Operation range down to -28°C High capacity at cold ambient Up to 13kW at -7/55°C LWT at 75°C down to -15°C Low sound: down to 28dBA at 3 meters distance Up to 75°C At 55°C average climate Domestic Hot Water up to up to +++ D A+++ + F A+

100 Setting new boundaries in heat pump technology Daikin Altherma 4: Improvements Continuous improvements delivered over-the-air to your installed base. More flexibility and efficiency – today and tomorrow. Improvement Applicable Outdoor 1 Update on R-290 protective zone Optimised protective zone requirements for more installation flexibility while maintaining high safety. EPSK EPSKS 2 Solutions for wind exposed applications Additional configuration options to ensure reliable operation in wind exposed environments. EPSK 3 Update on handling in operations Simplified processes for installation, commissioning, maintenance and repair. EPSK EPSKS 4 DCS Residential improvements Enhanced remote monitoring, diagnostics and control capabilities for faster fixes and fewer site visits. EPSK EPSKS 4 1 2 Protective zone update Wind covers DCS residential see p 240 Before (until Sep 2026) After (from Sep 2026) Example: in front of a wall Protective zone is reduced from 1,000mm to 500mm. 3 Certified partner update see p 85 500mm 500mm 500mm 300mm 300mm Note: For more details, please refer to the installation manuals and databook

101 R-290 Refrigerant J R-290 is a category A3 refrigerant (according to DIN EN 378). J Daikin provides the highest safety standards in the industry, incorporating advanced product features J Handling of A3 refrigerant is neither new nor unusual, however some precautions must be taken into account. Every home deserves a state-of-the-art heat pump. That’s why Daikin Altherma 4 combines R-290 refrigerant, a Daikin-developed compressor and a fan designed for efficient operation. Enjoy comfortable warmth and reliable performance throughout the heating season. We introduce to you our 4th generation, with R-290 refrigerant. R-290 Daikin Altherma 4 H operates silently down to 28dBA sound pressure at 3 meters, making days and nights undisturbed. Sound pressure scale 20dBA 30dBA 40dBA 60dBA 50dBA 100dBA 140dBA 28dBA Daikin Altherma 4 H falling leaves whisper fridge rain talking trumpet fireworks Engineered for whisper-quiet operation. Equipped with new soundbox and improved insulation technology to ensure peaceful environment. The sound box is mounted on the bottom plate instead of on the antivibration plate, with increased insulation. Insulating air layer Insulating material The innovative louvered grill was especially designed to minimize sound power to the impressive level of 48 – 54dBA, ensuring uninterrupted peace. J Contemporary sleek award winning design​ J Black louvered grill minimizes the visibility of the fan. J Integrates seamlessly with the surrounding environment by reflecting the surroundings on its cover and side panels

102 Sealed Switchbox: J Placed away from the refrigerant connections, on top of the fan J The full sealing prevents R-290 to get inside the switchbox Committed to high safety standards Daikin is committed to high safety standards: the Daikin Altherma 4 H heat pump is designed to set new industry safety standards, incorporating advanced features such as a high‑efficiency gas separator and factory-mounted anti-freeze valves. Gas leak sensor: J Detects potential refrigerant leaks J In case of leak detection, sensor automatically triggers the fan to run at maximum speed, effectively ventilating the area to prevent the buildup of a flammable gas cloud. J Minimum hourly self-inspection check, ensuring ongoing protection. Refrigerant vessel: J Protects refrigerant against possible damage during storage and transportation, that might cause leakages J After installation, R-290 is released into the refrigerant cycle J It can survive a 10 metres height drop without leakage Gas separator: J In the outdoor unit prevents R-290 to reach the indoor unit via the water circuit. Anti-freeze valve: J Protects the plate heat exchanger against freezing J Avoids R-290 leaks going from the refrigerant circuit to the water circuit

103 Intelligent control Straightforward and easy to use Daikin’s Altherma 4 H new intelligent control system is designed to enhance the user experience and installers efficiency. With advanced features like a 5" color touch screen, and streamlined commissioning, this system ensures reliable performance and easy management. It offers secure settings access and future-proof technology, making it the ultimate choice for seamless installation and maintenance. New intuitive MMI 5” touchscreen for better user experience. NEW Thanks to the Weather Dependent Curve – optimal comfort and high efficiency with automatically determined desired temperature. Easy customer access to main functionalities. Installer settings only visible in installer mode Block based easy scheduling for cooling and heating

104 BRC1HHDW(7) EPSKS-AV3 EPVX07A EPVX07A + EPSKS-AV3 Daikin Altherma 4 H F Floor standing air‑to‑water heat pump for heating, cooling and hot water J New intuitive MMI 5” touchscreen for better user experience J Inclusion of all hydraulic components means no third party components are required J PCB board and hydraulic components are located in the front for easy access J A combined stainless steel domestic hot water tank of 180 or 230L and heat pump for easy installation J Integrated back-up heater of 4.5 or 9kW EPSKS-AV3 EPVX07A 011-1W1131 Efficiency data EPVX + EPSKS 07AS18A4V + 04AV3 07S23A4V/9W + 04AV3 07AS18A4V + 06AV3 07S23A4V/9W + 06AV3 07AS18A4V + 07AV3 07S23A4V/9W + 07AV3 Heating capacity/ Power input A -7°C/W 35°C Max. kW 5.63/1.99 6.63/2.39 7.38/2.81 A -7°C/W 55°C Max. kW 5.22/2.46 6.3/2.97 8.2/3.87 A -7°C/W 60°C Max. kW 5.16/2.65 6.23/3.19 8.11/4.16 A -7°C/W 65°C Max. kW 5.1/2.83 6.16/3.42 8.02/4.45 A -2°C/W 35°C Max. kW 5.32/1.71 6.2/2.05 7.18/2.25 A -2°C/W 70°C Max. kW 4.81/2.62 5.73/3.14 5.73/3.14 A 2°C/W 35°C Max. kW 5.05/1.36 6.19/1.66 7.24/1.95 A 7°C/W 35°C Max. kW 5.25/1.1 7.24/1.53 8.3/1.76 A 7°C/W 45°C Max. kW 4.94/1.29 6.86/1.79 7.87/2.05 A 7°C/W 55°C Max. kW 4.88/1.47 6.77/2.04 7.77/2.34 Heating capacity Min./Nom./Max. kW -/5.25/5.22 -/5.25/6.30 -/5.25/8.20 Power input Heating Min./Nom./Max. kW -/1.02/- Space heating Average climate water outlet 55°C General SCOP 3.69 3.81 3.83 ηs (Seasonal heat. eff.) % 145 150 Seasonal space heating eff. class A++ (Range A+++ to D) A+++ (Range A+++ to D) Prated at -10°C kW 4.6 7.0 Average climate water outlet 35°C General SCOP 5.03 5.05 ηs (Seasonal heat. eff.) % 198 199 Seasonal space heating eff. class A+++ (Range A+++ to D) Prated at -10°C kW 6.1 Domestic hot water heating General Declared load profile L Average climate COPdhw 3.32 ηwh (water heating efficiency) % 133 Water heating energy efficiency class A+ (Range A+ to F) Indoor Unit EPVX 07AS18A4V 07AS23A4V/9W 07AS18A4V 07AS23A4V/9W 07AS18A4V 07AS23A4V/9W Casing Material Precoated galvanized steel + plastic Tank Insulation Material Polyurethane foam Heat loss kWh/24h 1.20(1) 1.40(1) 1.20(1) 1.40(1) 1.20(1) 1.40(1) Dimensions Unit HeightxWidthxDepth mm 1,650x595x625 1,850x595x625 1,650x595x625 1,850x595x625 1,650x595x625 1,850x595x625 Weight Unit kg 94.0 111 94.0 111 94.0 111 Tank Water volume l 180 230 180 230 180 230 Maximum water temperature °C 65.0 Maximum water pressure bar 10 Corrosion protection Pickling Operation range Indoor installation Ambient Min.~Max. °CDB 5~35(4) Heating Water side Min.~Max. °C 15~70 Domestic hot water Water side Min.~Max. °C 10~70 Sound power level Nom. dBA 45.0(2) Sound pressure level Nom. dBA 31.0(3) Water circuit Piping connections diameter inch G 1" (female) Water circuit - DHW side Piping connections Cold water in/Hot water out inch G 3/4" FEMALE Pump Type UPM4 LIN25-75 CESSMD 6 DKI 3h Outdoor Unit EPSKS 04AV3 06AV3 07AV3 Dimensions Unit HeightxWidthxDepth mm 958x1,220x535 Weight Unit kg 109 Compressor Quantity / Type 1 / Hermetically sealed swing compressor Operation range Heating/Cooling Min.~Max. °CDB -28~25/10~43 Domestic hot water Min.~Max. °CDB -28~40 Refrigerant Type/GWP/Control R-290/3.0/Expansion valve Charge kg/tCO₂eq 0.830/0.0025 Sound power level Heating/Cooling Nom./Nom. dBA 48.2/56.7 Sound pressure level Heating/Cooling Nom./Nom. dBA 29.1/37.3 Night quiet mode Heating/Cooling dBA 29.1/35.6 31.6/35.6 33.0(5)/35.6 Piping connections Piping length OU - IU Max. m 20 Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/220-240 Current Recommended fuses A 16 25 (1)Based on dT of 45 K | (2)Measured with a pressure drop of 10kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. | (3)Value measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. The sound pressure level mentioned is measured with a pressure drop of 10kPa in the heating system at an operating condition of leaving water temperature 47-55°C in a room with an ambient temperature of 20°C. DB/WB 7°C/6°C | (4)Depends on operation mode, refer to installation manual. | (5)Measured at LWC 47-55°C; Ta DB/WB 7°C/6°C. Whisper quiet Onecta app Guaranteed operation down to -28°C R-290 70°C At 35°C average climate At 55°C average climate +++ D A+++ up to + F A+

105 BRC1HHDK(7) R-290 up to up to 75°C LWT 75°C at -15°C At 35°C average climate At 55°C average climate +++ D A+++ + F A+ Whisper quiet Onecta app Guaranteed operation down to -28°C EPSK06-14AV3/W1 EPVX10-14A4V/9W EPVX10-14A4V/9W + EPSK06-14AV3/W1 Daikin Altherma 4 H F Floor standing air‑to‑water heat pump for heating, cooling and hot water J New intuitive MMI 5” touchscreen for better user experience J Inclusion of all hydraulic components means no third party components are required J PCB board and hydraulic components are located in the front for easy access J A combined stainless steel domestic hot water tank of 180 or 230L and heat pump for easy installation J Integrated back-up heater of 4.5 or 9kW EPSK06-10AV3 EPSK08-10AW1 EPSK12-14AW1 011-1W0929 011-1W0930 011-1W0931 011-1W0933 011-1W0934 011-1W1097 EPVX10A4V EPVX10A9W EPVX14A4V EPVX14A9W Efficiency data EPVX + EPSK 10S18/S23A4V/9W + 06AV3 10S18/S23A4V/9W + 08AV3 10S18/S23A4V/9W + 10AV3 10S18/S23A4V/9W + 08AW1 10S18/S23A4V/9W + 10AW1 14S18/S23A4V/9W + 12AW1 14S18/S23A4V/9W + 14AW1 Heating capacity/ Power input A -7°C/W 35°C Max. kW 6.23/1.84 7.83/2.40 9.10/3.20 7.83/2.40 9.10/3.20 10.43/3.34 13.73/4.91 A -7°C/W 55°C Max. kW 6.63/2.61 7.86/3.06 9.48/4.07 7.86/3.06 9.10/3.20 12.14/5.00 13.3/5.66 A -7°C/W 60°C Max. kW 5.53/2.29 7.76/3.37 9.36/4.51 7.76/3.37 9.36/4.51 11.37/5.28 13.12/6.10 A -7°C/W 65°C Max. kW 5.18/2.51 6.69/3.55 7.14/3.99 6.69/3.55 7.14/3.99 11.22/5.66 12.94/6.53 A -2°C/W 35°C Max. kW 5.65/1.52 6.96/2.08 7.72/2.59 6.96/2.08 7.72/2.59 9.551/3.13 12.87/4.34 A -2°C/W 70°C Max. kW 5.46/2.60 6.76/3.35 7.43/4.16 6.76/3.35 7.43/4.16 9.588/5.16 9.962/5.54 A 2°C/W 35°C Max. kW 4.86/1.24 5.91/1.69 6.91/2.17 5.91/1.69 6.91/2.17 8.971/2.63 11.25/3.23 A 7°C/W 35°C Max. kW 5.73/1.07 7.48/1.44 9.70/2.11 7.48/1.44 9.70/2.11 12.27/2.29 10.74/2.57 A 7°C/W 45°C Max. kW 5.82/1.30 7.61/1.75 9.87/2.56 7.61/1.75 9.87/2.56 12.08/3.02 15.16/3.8 A 7°C/W 55°C Max. kW 5.92/1.53 7.74/2.05 10.04/3.01 7.74/2.05 10.04/3.01 12.16/3.55 15.26/4.45 Heating capacity Nom. kW 5.81 7.62 8.11 7.62 8.11 10.2 Power input Heating kW 1.12 1.52 1.64 1.52 1.64 1.86 Space heating Average climate water outlet 55°C General SCOP 3.91 3.97 4.02 3.94 3.99 4.04 3.84 ηs (Seasonal heat. eff.) % 153 156 158 155 157 159 150 Seasonal space heating eff. class A+++ (Range A+++ to D) Prated at -10°C kW 6.5 7.5 8.5 7.5 8.5 10.5 14 Average climate water outlet 35°C General SCOP 5.12 5.15 5.14 4.96 ηs (Seasonal heat. eff.) % 202 203 202 203 195 Seasonal space heating eff. class A+++ (Range A+++ to D) Prated at -10°C kW 6.5 7.5 8.5 7.5 8.5 10 12 Domestic hot water heating General Declared load profile L Average climate COPdhw 2.93 2.91 3.03 ηwh (water heating efficiency) % 117 116 121 Water heating energy efficiency class A+ (Range A+ to F) Indoor Unit EPVX 10S18/S23A4V/9W 10S18/S23A4V/9W 14S18/S23A4V/9W Casing Material Precoated galvanized steel + plastic Tank Insulation Material Polyurethane foam Heat loss kWh/24h 1.20/1.40 Dimensions Unit HeightxWidthxDepth mm 1,650x595x625/1,850x595x625 Weight Unit kg 94.0/111 Tank Water volume l 180/230 Maximum water temperature °C 65 Maximum water pressure bar 10 Corrosion protection Pickling Operation range Indoor installation Ambient Min.~Max. °CDB 5~35(4) Heating Water side Min.~Max. °C 15~70 15~75 Domestic hot water Water side Min.~Max. °C 10~75 Sound power level Nom. dBA 45.0(1) Sound pressure level Nom. dBA 31.0(2) Water circuit Piping connections diameter inch G 1" (female) Water circuit - DHW side Piping connections Cold water in/Hot water out inch G 3/4" FEMALE Pump Type Grundfos UPM4XL LIN 25-90 Grundfos UPM10XL LIN 25-125 Outdoor Unit EPSK 06AV3 08AV3 10AV3 08AW1 10AW1 12AW1 14AW1 Dimensions Unit HeightxWidthxDepth mm 1,123x1,330x604 Weight Unit kg 174 178 191 Compressor Quantity / Type 1 / Hermetically sealed scroll compressor Operation range Heating/Cooling Min.~Max. °CDB -28~25/10~43 Domestic hot water Min.~Max. °CDB -28~40 Refrigerant Type/GWP/Control R-290/3/Expansion valve Charge kg/tCO₂eq 1/0.003 Sound power level Heating/Cooling Nom./Nom. dBA 45(5)/52.2(6) 45(5)/53(6) 47(5)/53.2(6) 45(5)/53(6) 47(5)/53.2(6) 52(5)/62(6) 52(5)/63(6) Sound pressure level Heating/Cooling Nom./Nom. dBA 32.6(5)/36.9(6) 32.4(5)/37.2(6) 32.8(5)/37.3(6) 32.4(5)/37.2(6) 32.8(5)/37.3(6) 38(5)/47(6) 38(5)/48(6) Night quiet mode Heating/Cooling dBA 29.5(5)/30.8(6) 30(5)/30.8(6) 33(5)/30.8(6) 30(5)/30.8(6) 33(5)/30.8(6) 38(5)/41(6) Piping connections Piping length OU - IU Max. m 20(7)/30(8) 20(7)/50(8) Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3~/50/400 Current Recommended fuses A 25 16 (1)Measured with a pressure drop of 10kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. | (2)Value measured in an anechoic room at 1m distance from the unit. It is a relative value, depending on the distance and acoustic environment. The sound pressure level mentioned is measured with a pressure drop of 10kPa in the heating system at an operating condition of leaving water temperature 47-55°C in a room with an ambient temperature of 20°C. DB/WB 7°C/6°C | (3)Refer to operation range of the unit. | (4)Depends on operation mode, refer to installation manual. | (5)Measured at LWC 47-55°C; Ta DB/WB 7°C/6°C. | (6)Measured at LWC 12-7°C; Ta 35°C. | (7)1 1/4” field piping | (8)1 1/2” field piping

106 BRC1HHDK(7) EPSKS-AV3 Whisper quiet Onecta app Guaranteed operation down to -28°C R-290 70°C At 35°C average climate At 55°C average climate +++ D A+++ up to + F A+ EPSX07A EPSX07A + EPSKS-AV3 Daikin Altherma 4 H ECH2O Floor standing air‑to‑water heat pump for heating and hot water with thermal solar support J New intuitive MMI 5” touchscreen for better user experience J Integrated back-up heater of 9kW J Integrated solar unit, offering top comfort in heating and hot water J Optimised use of renewable energy: uses heat pump technology for heating and solar support for space heating and domestic hot water production J Fresh water principle: hygienic water, with no need for thermal legionella disinfection J Tank designed to prevent corrosion, anode degradation, scale buildup, lime deposits, and water loss through safety valve mechanisms J Solar support of domestic hot water with pressureless (drain-back) solar system J Heat loss is reduced to a minimum thanks to the high quality insulation J App control possible for managing heating, hot water and cooling operation Efficiency data EPSX + EPSKS 07P30A + 04AV3 07P50A + 04AV3 07P30A + 06AV3 07P50A + 06AV3 07P30A + 07AV3 07P50A + 07AV3 Heating capacity/ Power input A -7°C/W 35°C Max. kW 5.63/1.99 6.63/2.39 7.38/2.81 A -7°C/W 55°C Max. kW 5.22/2.46 6.3/2.97 8.2/3.87 A -7°C/W 60°C Max. kW 5.16/2.65 6.23/3.19 8.11/4.16 A -7°C/W 65°C Max. kW 5.1/2.83 6.16/3.42 8.02/4.45 A -2°C/W 35°C Max. kW 5.32/1.71 6.2/2.05 7.18/2.25 A -2°C/W 70°C Max. kW 4.81/2.62 5.73/3.14 5.73/3.14 A 2°C/W 35°C Max. kW 5.05/1.36 6.19/1.66 7.24/1.95 A 7°C/W 35°C Max. kW 5.25/1.1 7.24/1.53 8.3/1.76 A 7°C/W 45°C Max. kW 4.94/1.29 6.86/1.79 7.87/2.05 A 7°C/W 55°C Max. kW 4.88/1.47 6.77/2.04 7.77/2.34 Heating capacity Min./Nom./Max. kW -/5.25/5.22 -/5.25/6.30 -/5.25/8.20 Power input Heating Min./Nom./Max. kW -/1.02/- Space heating Average climate water outlet 55°C General SCOP 3.69 3.81 3.83 ηs (Seasonal heat. eff.) % 145 150 Seasonal space heating eff. class A++ (Range A+++ to D) A+++ (Range A+++ to D) Prated at -10°C kW 4.6 7.0 Average climate water outlet 35°C General SCOP 5.03 5.05 ηs (Seasonal heat. eff.) % 198 199 Seasonal space heating eff. class A+++ (Range A+++ to D) Prated at -10°C kW 6.1 Domestic hot water heating General Declared load profile L XL L XL L XL Average climate COPdhw 2.91 3.35 2.91 3.35 2.91 3.35 ηwh (water heating efficiency) % 116 134 116 134 116 134 Water heating energy efficiency class A+ (Range A+ to F) Indoor Unit EPSX 07P30A 07P50A 07P30A 07P50A 07P30A 07P50A Casing Material Impact resistant polypropylene Tank Insulation Material HFC-free Polyurethane foam Heat loss kWh/24h 15.00 17.00 15.00 17.00 15.00 17.00 Dimensions Unit HeightxWidthxDepth mm 1,914x590x671 1,906x785x837 1,914x590x671 1,906x785x837 1,914x590x671 1,906x785x837 Weight Unit kg 76.0 97.0 76.0 97.0 76.0 97.0 Tank Water volume l 294 477 294 477 294 477 Maximum water temperature °C 85.0 Operation range Indoor installation Ambient Min.~Max. °CDB 5~35 Heating Water side Min.~Max. °C 15~70 Domestic hot water Water side Min.~Max. °C 10~70 Sound power level Nom. dBA 47.0 Sound pressure level Nom. dBA 24.8 Water circuit Piping connections diameter inch G 1" female screw connection, quick connection Water circuit - DHW side Piping connections Cold water in/Hot water out inch G 1" male thread Pump Type UPM4 LIN25-90 CESSMD 6 DKI 3h Outdoor Unit EPSKS 04AV3 04AV3 06AV3 06AV3 07AV3 07AV3 Dimensions Unit HeightxWidthxDepth mm 958x1,220x535 Weight Unit kg 109 Compressor Quantity / Type 1 / Hermetically sealed swing compressor Operation range Heating/Cooling Min.~Max. °CDB -28.0~25/10~43 Domestic hot water Min.~Max. °CDB -28~40 Refrigerant Type/GWP/Control R-290/3.0/Expansion valve Charge kg/tCO₂eq 0.830/0.0025 Sound power level Heating/Cooling Nom./Nom. dBA 48.2/56.7 Sound pressure level Heating/Cooling Nom./Nom. dBA 29.1/37.3 Night quiet mode Heating/Cooling dBA 29.1/35.6 31.6/35.6 33.0(2)/35.6 Piping connections Piping length OU - IU Max. m 20 Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/220-240 Current Recommended fuses A 16 25 (1)Refer to drawing operation limits | (2)Measured at LWC 47-55°C; Ta DB/WB 7°C/6°C. 011-1W1132 011-1W1133 EPSKS-AV3 EPSX07A

107 BRC1HHDS(7) R-290 up to up to 75°C LWT 75°C at -15°C At 35°C average climate At 55°C average climate +++ D A+++ F A+ Whisper quiet Onecta app Guaranteed operation down to -28°C EPSK06-14AV3/W1 EPSX10-14A EPSX10-14A + EPSK06-14AV3/W1 Daikin Altherma 4 H ECH2O Floor standing air‑to‑water heat pump for heating and hot water with thermal solar support J New intuitive MMI 5” touchscreen for better user experience J Integrated back-up heater of 9kW J Integrated solar unit, offering top comfort in heating and hot water J Optimised use of renewable energy: uses heat pump technology for heating and solar support for space heating and domestic hot water production J Fresh water principle: hygienic water, with no need for thermal legionella disinfection J Tank designed to prevent corrosion, anode degradation, scale buildup, lime deposits, and water loss through safety valve mechanisms J Solar support of domestic hot water with pressureless (drain-back) solar system J Heat loss is reduced to a minimum thanks to the high quality insulation J App control possible for managing heating, hot water and cooling operation Efficiency data EPSX + EPSK 10P30/P50A + 06AV3 10P30/P50A + 08AV3 10P30/P50A + 10AV3 10P30/P50A + 08AW1 10P30/P50A + 10AW1 14P30/P50A + 12AW1 14P30/P50A + 14AW1 Heating capacity/ Power input A -7°C/W 35°C Max. kW 6.23/1.84 7.83/2.40 9.10/3.20 7.83/2.40 9.10/3.20 10.43/3.34 13.73/4.91 A -7°C/W 55°C Max. kW 6.63/2.61 7.86/3.06 9.48/4.07 7.86/3.06 9.10/3.20 12.14/5.00 13.3/5.66 A -7°C/W 60°C Max. kW 5.53/2.29 7.76/3.37 9.36/4.51 7.76/3.37 9.36/4.51 11.37/5.28 13.12/6.10 A -7°C/W 65°C Max. kW 5.18/2.51 6.69/3.55 7.14/3.99 6.69/3.55 7.14/3.99 11.22/5.66 12.94/6.53 A -2°C/W 35°C Max. kW 5.65/1.52 6.96/2.08 7.72/2.59 6.96/2.08 7.72/2.59 9.551/3.13 12.87/4.34 A -2°C/W 70°C Max. kW 5.46/2.60 6.76/3.35 7.43/4.16 6.76/3.35 7.43/4.16 9.588/5.16 9.962/5.54 A 2°C/W 35°C Max. kW 4.86/1.24 5.91/1.69 6.91/2.17 5.91/1.69 6.91/2.17 8.971/2.63 11.25/3.23 A 7°C/W 35°C Max. kW 5.73/1.07 7.48/1.44 9.70/2.11 7.48/1.44 9.70/2.11 12.27/2.29 10.74/2.57 A 7°C/W 45°C Max. kW 5.82/1.30 7.61/1.75 9.87/2.56 7.61/1.75 9.87/2.56 12.08/3.02 15.16/3.8 A 7°C/W 55°C Max. kW 5.92/1.53 7.74/2.05 10.04/3.01 7.74/2.05 10.04/3.01 12.16/3.55 15.26/4.45 Heating capacity Nom. kW 5.81 7.62 8.11 7.62 8.11 10.2 Power input Heating kW 1.12 1.52 1.64 1.52 1.64 1.86 Space heating Average climate water outlet 55°C General SCOP 3.91 3.97 4.02 3.94 3.99 4.04 3.84 ηs (Seasonal heat. eff.) % 153 156 158 155 157 159 150 Seasonal space heating eff. class A+++ (Range A+++ to D) Prated at -10°C kW 6.5 7.5 8.5 7.5 8.5 10.5 14 Average climate water outlet 35°C General SCOP 5.12 5.15 5.14 4.96 ηs (Seasonal heat. eff.) % 202 203 202 203 195 Seasonal space heating eff. class A+++ (Range A+++ to D) Prated at -10°C kW 6.5 7.5 8.5 7.5 8.5 10 12 Domestic hot water heating General Declared load profile L Average climate COPdhw 2.52 2.77 ηwh (water heating efficiency) % 101 110 Water heating energy efficiency class A (Range A+ to F) Indoor Unit EPSX 10P30/P50 14P30/P50 Casing Material Impact resistant polypropylene Tank Insulation Material HFC-free Polyurethane foam Heat loss kWh/24h 15.0/17.0 Dimensions Unit HeightxWidthxDepth mm 1,914x590x671/1,906x785x837 Weight Unit kg 74.0/97.0 Tank Water volume l 294/477 Maximum water temperature °C 85.0 Operation range Indoor installation Ambient Min.~Max. °CDB 5~35 Heating Water side Min.~Max. °C 15~70 15~75 Domestic hot water Water side Min.~Max. °C 10~75 Sound power level Nom. dBA 49.0 Sound pressure level Nom. dBA 35.0 Water circuit Piping connections diameter inch G 1" female screw connection, quick connection Water circuit - DHW side Piping connections Cold water in/Hot water out inch G 1" male thread Pump Type Grundfos UPM4XL K LIN 25-90 CESSMD P3C DKI Grundfos UPM10XL LIN 25-125 CESMED 6 DKI Outdoor Unit EPSK 06AV3 08AV3 10AV3 08AW1 10AW1 12AW1 14AW1 Dimensions Unit HeightxWidthxDepth mm 1,123x1,330x604 Weight Unit kg 174 178 191 Compressor Quantity / Type 1 / Hermetically sealed scroll compressor Operation range Heating/Cooling Min.~Max. °CDB -28~25/10~43 Domestic hot water Min.~Max. °CDB -28~40 Refrigerant Type/GWP/Control R-290/3/Expansion valve Charge kg/tCO₂eq 1/0.003 1.25/0.0038 Sound power level Heating/Cooling Nom./Nom. dBA 45(2)/52.2(3) 45(2)/53(3) 47(2)/53.2(3) 45(2)/53(3) 47(2)/53.2(3) 52(2)/62(3) 52(2)/63(3) Sound pressure level Heating/Cooling Nom./Nom. dBA 32.6(2)/36.9(3) 32.4(2)/37.2(3) 32.8(2)/37.3(3) 32.4(2)/37.2(3) 32.8(2)/37.3(3) 38(2)/47(3) 38(2)/48(3) Night quiet mode Heating/Cooling dBA 29.5(2)/30.8(3) 30(2)/30.8(3) 33(2)/30.8(3) 30(2)/30.8(3) 33(2)/30.8(3) 38(2)/41(3) Piping connections Piping length OU - IU Max. m 20(4)/30(5) Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3~/50/400 Current Recommended fuses A 25 16 (1)Refer to drawing operation limits | (2)Measured at LWC 47-55°C; Ta DB/WB 7°C/6°C. | (3)Measured at LWC 12-7°C; Ta 35°C. | (4)1 1/4” field piping | (5)1 1/2” field piping 011-1W0935 011-1W0937 011-1W0938 011-1W0939 011-1W0940 011-1W1098 EPSK06-10AV3 EPSK08-10AW1 EPSK12-14AW1 EPSX10A EPSX14A

RkJQdWJsaXNoZXIy MTE0MTkzMg==