133 ERRA08-12EW17 BRC1HHDW(7) ELV(H-X)-E6V_E9W Daikin Altherma 3 R MT F Floor standing air‑to‑water heat pump for heating, cooling and hot water J A combined stainless steel domestic hot water tank of 180 or 230L and heat pump for easy installation J For hot water, heating and cooling J Quick configuration in 9 steps in a high resolution colour interface wizard J Inclusion of all hydraulic components means no third party components are required J The unit’s sleek design blends in with other household appliances. ELVX-E6V ELVX-E9W ERRA-EW17 ERRA-EV37 Efficiency data ELVX + ERRA 12S18/23E6V/9W+08EV37 12S18/23E6V/9W+10EV37 12S18/23E6V/9W+12EV37 12S18/23E6V/9W+08EW17 12S18/23E6V/9W+10EW17 12S18/23E6V/9W+12EW17 Heating capacity/ Power input A -7°C/W 35°C Max. 7.49/2.46 8.843/3.00 10.27/3.53 7.49/2.38 8.843/2.88 10.27/3.41 A -7°C/W 55°C Max. 7.55/3.68 9.103/4.19 10.57/4.95 7.55/3.54 9.103/4.03 10.57/4.79 A -7°C/W 60°C Max. 7.754/3.93 9.746/4.98 11.32/5.88 7.754/3.75 9.746/4.77 11.32/5.67 A -7°C/W 65°C Max. 7.996/4.41 9.246/5.13 10.74/6.06 7.996/4.19 9.246/4.90 10.74/5.82 A -2°C/W 35°C Max. 7.950/2.52 8.803/2.88 8.844/3.03 7.950/2.42 8.803/2.77 8.844/2.92 A 2°C/W 35°C Max. 6.52/1.83 8.049/2.15 8.092/2.29 6.52/1.77 8.049/2.08 8.092/2.22 A 7°C/W 35°C Max. 7.947/1.69 9.247/2.04 9.97/2.28 7.947/1.62 9.247/1.97 9.97/2.21 A 7°C/W 45°C Max. 7.816/2.14 9.096/2.59 9.806/2.88 7.816/2.06 9.096/2.49 9.806/2.78 A 7°C/W 55°C Max. 9.117/3.08 10.60/3.72 11.43/4.13 9.117/2.91 10.60/3.53 11.43/3.93 Heating capacity Min./Nom./Max. kW 3.45(1)/6.17(2)/7.95(1) 3.45(1)/6.17(2)/9.25(1) 3.45(1)/6.17(2)/9.97(1) 3.45(1)/6.17(2)/7.95(1) 3.45(1)/6.17(2)/9.25(1) 3.45(1)/6.17(2)/9.97(1) Power input Heating Min./Nom./Max. kW 0.72(3)/1.25(2)/1.69(3) 0.72(3)/1.25(2)/2.04(3) 0.72(3)/1.25(2)/2.28(3) 0.70(3)/1.21(2)/1.63(3) 0.70(3)/1.21(2)/1.98(3) 0.70(3)/1.21(2)/2.21(3) Space heating Average climate water outlet 55°C General SCOP 3.58 ηs (Seasonal heat. eff.) % 140 Seasonal space heating eff. class A++ (Range A+++ to D) Prated at -10°C kW 12.5 Average climate water outlet 35°C General SCOP 4.79 4.82 4.95 4.98 4.98 ηs (Seasonal heat. eff.) % 188 190 195 196 196 Seasonal space heating eff. class A+++ (Range A+++ to D) Prated at -10°C kW 8.3 Domestic hot water heating General Declared load profile L Average climate COPdhw 2.72 2.96 2.72 2.96 2.72 2.96 2.80 3.05 2.80 3.05 2.80 3.05 ηwh (water heating efficiency) % 117 126 117 126 117 126 120 130 120 130 120 130 Water heating energy efficiency class A+ (Range A+ to F) Indoor Unit ELVX 12S18/23E6V/9W Casing Material Precoated sheet metal Tank Insulation Material Polyurethane foam Heat loss kWh/24h 1.2/1.4 Dimensions Unit HeightxWidthxDepth mm 1,655x595x634/1,855x595x634 Weight Unit kg 120/129 Tank Water volume l 180/230 Maximum water temperature °C 70.0 Maximum water pressure bar 10 Corrosion protection Pickling Operation range Indoor installation Ambient Min.~Max. °CDB 5~35 Heating Water side Min.~Max. °C 15~65 Domestic hot water Water side Min.~Max. °C 25-62 Sound power level Nom. dBA 44.0 Sound pressure level Nom. dBA 30.0 Water circuit Piping connections diameter inch G 1" (female) Water circuit - DHW side Piping connections Cold water in/Hot water out inch G 3/4" FEMALE Pump Type Grundfos UPM4L K 15-75 130 9 DKI Outdoor Unit ERRA 08EV37 10EV37 12EV37 08EW17 10EW17 12EW17 Dimensions Unit HeightxWidthxDepth mm 1,003x1,270x533 Weight Unit kg 107 Compressor Quantity / Type 1 / Hermetically sealed swing compressor Operation range Heating/Cooling Min.~Max. °CDB -25.0~25/10~43 Domestic hot water Min.~Max. °CDB -25~35 Refrigerant Type/GWP/Control R-32/675.0/Expansion valve Charge kg/tCO₂eq 3.25/2.19 Sound power level Heating/Cooling Nom./Nom. dBA 56.0(4)/60.1(5) 56.0(4)/60.6(5) 56.0(4)/61.5(5) 56.0(4)/61.2(5) 56.0(4)/61.4(5) 56.0(4)/60.9(5) Sound pressure level Heating/Cooling Nom./Nom. dBA 40.6(6)/47.0(7) 40.6(6)/47.4(7) 40.6(6)/48.5(7) 41.1(6)/47.1(7) 41.1(6)/47.2(7) Night quiet mode Heating/Cooling dBA 43.2(6)/43.7(7) 43.2(6)/44.0(7) 43.2(6)/44.0(7) Piping connections Gas/Liquid OD mm 15.9/6.35 Piping length OU - IU Max. m 50 Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3~/50/400 Current Recommended fuses A 32 16 (1)Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C | (2)Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (3)Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 | (4)Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (5)Condition 2: cooling Ta 35°C - LWE 7°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (6)Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings. | (7)The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. 011-1W0651 011-1W0652 011-1W0653 011-1W0654 011-1W0655 011-1W0656 011-1W0651 011-1W0652 011-1W0653 011-1W0654 011-1W0655 011-1W0656 Voice control Onecta app Guaranteed operation down to -25°C 65°C up to +++ D A+++ + F A+ ELVX-E6V/9W + ERRA08-12EV37/EW17
RkJQdWJsaXNoZXIy MTE0MTkzMg==