136 ERRA08-12EW17 ELSHB-E BRC1HHDW(7) Daikin Altherma 3 R MT ECH2O Floor standing air‑to‑water heat pump for bivalent heating and hot water with thermal solar support J Integrated solar unit, offering top comfort in heating and hot water J Tank designed to prevent corrosion, anode degradation, scale buildup, lime deposits, and water loss through safety valve mechanisms J Quick configuration in 9 steps in a high resolution colour interface wizard J Optimised use of renewable energy: uses heat pump technology for heating and solar support for space heating and domestic hot water production J Fresh water principle: hygienic water, with no need for thermal legionella disinfection ELSHB-E ERRA-EW17 ERRA-EV37 011-1W0657 011-1W0658 011-1W0657 011-1W0658 Efficiency data ELSHB + ERRA 12P30/50E+08EV37 12P30/50E+10EV37 12P30/50E+12EV37 12P30/50E+08EW17 12P30/50E+10EW17 12P30/50E+12EW17 Heating capacity/ Power input A -7°C/W 35°C Max. kW 7.49/2.46 8.843/3.00 10.27/3.53 7.49/2.38 8.843/2.88 10.27/3.41 A -7°C/W 55°C Max. kW 7.55/3.68 9.103/4.19 10.57/4.95 7.55/3.54 9.103/4.03 10.57/4.79 A -7°C/W 60°C Max. kW 7.754/3.93 9.746/4.98 11.32/5.88 7.754/3.75 9.746/4.77 11.32/5.67 A -7°C/W 65°C Max. kW 7.996/4.41 9.246/5.13 10.74/6.06 7.996/4.19 9.246/4.90 10.74/5.82 A -2°C/W 35°C Max. kW 7.950/2.52 8.803/2.88 8.844/3.03 7.950/2.42 8.803/2.77 8.844/2.92 A 2°C/W 35°C Max. kW 6.52/1.83 8.049/2.15 8.092/2.29 6.52/1.77 8.049/2.08 8.092/2.22 A 7°C/W 35°C Max. kW 7.947/1.69 9.247/2.04 9.97/2.28 7.947/1.62 9.247/1.97 9.97/2.21 A 7°C/W 45°C Max. kW 7.816/2.14 9.096/2.59 9.806/2.88 7.816/2.06 9.096/2.49 9.806/2.78 A 7°C/W 55°C Max. kW 9.117/3.08 10.60/3.72 11.43/4.13 9.117/2.91 10.60/3.53 11.43/3.93 Heating capacity Min./Nom./Max. kW 3.45(1)/6.17(2)/7.95(1) 3.45(1)/6.17(2)/9.25(1) 3.45(1)/6.17(2)/9.97(1) 3.45(1)/6.17(2)/7.95(1) 3.45(1)/6.17(2)/9.25(1) 3.45(1)/6.17(2)/9.97(1) Power input Heating Min./Nom./Max. kW 0.72(3)/1.25(2)/1.69(3) 0.72(3)/1.25(2)/2.04(3) 0.72(3)/1.25(2)/2.28(3) 0.70(3)/1.21(2)/1.63(3) 0.70(3)/1.21(2)/1.98(3) 0.70(3)/1.21(2)/2.21(3) Space heating Average climate water outlet 55°C General SCOP 3.34 3.44 3.42 3.43 3.53 ηs (Seasonal heat. eff.) % 130 131 135 134 138 Seasonal space heating eff. class A++ (Range A+++ to D) Prated at -10°C kW 12.5 Average climate water outlet 35°C General SCOP 4.69 4.71 4.81 4.84 ηs (Seasonal heat. eff.) % 184 186 190 191 Seasonal space heating eff. class A+++ (Range A+++ to D) Prated at -10°C kW 8.3 Domestic hot water heating General Declared load profile L XL L XL L XL L XL L XL L XL Average climate COPdhw 2.75 3.19 2.75 3.19 2.75 3.19 2.83 3.29 2.83 3.29 2.83 3.29 ηwh (water heating efficiency) % 116 132 116 132 116 132 119 136 119 136 119 136 Water heating energy efficiency class A+ (Range A+ to F) Indoor Unit ELSHB 12P30/50E Casing Material Impact resistant polypropylene Tank Insulation Material HFC-free Polyurethane foam Heat loss kWh/24h 1.5/1.7 Dimensions Unit HeightxWidthxDepth mm 1,891x594x680/1,910x792x817 Weight Unit kg 93.0/115 Tank Water volume l 294/477 Maximum water temperature °C 85.0 Operation range Indoor installation Ambient Min.~Max. °CDB 5~35 Heating Water side Min.~Max. °C 15(4)~65(4) Domestic hot water Water side Min.~Max. °C 25(4)~62(4) Sound power level Nom. dBA 44.7 Sound pressure level Nom. dBA 36.8 Water circuit Piping connections diameter inch G 1" (male) Water circuit - DHW side Piping connections Cold water in/Hot water out inch G 1" (male) Pump Type Grundfos UPM4L K 20-75 CHBL 3 RT Outdoor Unit ERRA 08EV37 10EV37 12EV37 08EW17 10EW17 12EW17 Dimensions Unit HeightxWidthxDepth mm 1,003x1,270x533 Weight Unit kg 107 Compressor Quantity / Type 1 / Hermetically sealed swing compressor Operation range Heating/Cooling Min.~Max. °CDB -25.0~25/10~43 Domestic hot water Min.~Max. °CDB -25~35 Refrigerant Type/GWP/Control R-32/675.0/Expansion valve Charge kg/tCO₂eq 3.25/2.19 Sound power level Heating/Cooling Nom./Nom. dBA 56.0(5)/60.1(6) 56.0(5)/60.6(6) 56.0(5)/61.5(6) 56.0(5)/61.2(6) 56.0(5)/61.4(6) 56.0(5)/60.9(6) Sound pressure level Heating/Cooling Nom./Nom. dBA 40.6(7)/47.0(8) 40.6(7)/47.4(8) 40.6(7)/48.5(8) 41.1(7)/47.1(8) 41.1(7)/47.2(8) Night quiet mode Heating/Cooling dBA 43.2(7)/43.7(8) 43.2(7)/44.0(8) Piping connections Gas/Liquid OD mm 15.9/6.35 Piping length OU - IU Max. m 50 Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3~/50/400 Current Recommended fuses A 32 16 (1)Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C | (2)Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (3)Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 | (4)For more details, see operation range drawing | (5)Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (6)Condition 2: cooling Ta 35°C - LWE 7°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (7)Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings. | (8)The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Solar panel Fresh hot water Voice control Onecta app Guaranteed operation down to -25°C ELSHB-E + ERRA08-12EV37/EW17 65°C up to +++ D A+++ + F A+
RkJQdWJsaXNoZXIy MTE0MTkzMg==