140 ERRA08-12EW1 BRC1HHDW(7) ELBX-E6V/E9W 65°C up to +++ D A+++ Voice control Onecta app Guaranteed operation down to -25°C ELBX-E6V/9W + ERRA08-12EV37/EW17 Daikin Altherma 3 R MT W Wall mounted reversible air‑to‑water heat pump ideal for low energy houses J Quick configuration in 9 steps in a high resolution colour interface wizard J Compact dimensions allows for small installation space, as almost no side clearances are required. J Combine with a stainless steel tank or ECH 2O thermal store. J Inclusion of all hydraulic components means no third party components are required J The unit’s sleek design blends in with other household appliances. ELBX-E6V ELBX-E9W ERRA-EW17 ERRA-EV37 011-1W0651 011-1W0653 011-1W0655 Efficiency data ELBX + ERRA 12E6V/9W+08EV37 12E6V/9W+10EV37 12E6V/9W+12EV37 12E6V/9W+08EW17 12E6V/9W+10EW17 12E6V/9W+12EW17 Heating capacity/ Power input A -7°C/W 35°C Max. kW 7.49/2.46 8.843/3.00 10.27/3.53 7.49/2.38 8.843/2.88 10.27/3.41 A -7°C/W 55°C Max. kW 7.55/3.68 9.103/4.19 10.57/4.95 7.55/3.54 9.103/4.03 10.57/4.79 A -7°C/W 60°C Max. kW 7.754/3.93 9.746/4.98 11.32/5.88 7.754/3.75 9.746/4.77 11.32/5.67 A -7°C/W 65°C Max. kW 7.996/4.41 9.246/5.13 10.74/6.06 7.996/4.19 9.246/4.90 10.74/5.82 A -2°C/W 35°C Max. kW 7.950/2.52 8.803/2.88 8.844/3.03 7.950/2.42 8.803/2.77 8.844/2.92 A 2°C/W 35°C Max. kW 6.52/1.83 8.049/2.15 8.092/2.29 6.52/1.77 8.049/2.08 8.092/2.22 A 7°C/W 35°C Max. kW 7.947/1.69 9.247/2.04 9.97/2.28 7.947/1.62 9.247/1.97 9.97/2.21 A 7°C/W 45°C Max. kW 7.816/2.14 9.096/2.59 9.806/2.88 7.816/2.06 9.096/2.49 9.806/2.78 A 7°C/W 55°C Max. kW 9.117/3.08 10.60/3.72 11.43/4.13 9.117/2.91 10.60/3.53 11.43/3.93 Heating capacity Min./Nom./Max. kW 3.45(1)/6.17(2)/7.95(1) 3.45(1)/6.17(2)/9.25(1) 3.45(1)/6.17(2)/9.97(1) 3.45(1)/6.17(2)/7.95(1) 3.45(1)/6.17(2)/9.25(1) 3.45(1)/6.17(2)/9.97(1) Power input Heating Min./Nom./Max. kW 0.72(3)/1.25(2)/1.69(3) 0.72(3)/1.25(2)/2.04(3) 0.72(3)/1.25(2)/2.28(3) 0.70(3)/1.21(2)/1.63(3) 0.70(3)/1.21(2)/1.98(3) 0.70(3)/1.21(2)/2.21(3) Space heating Average climate water outlet 55°C General SCOP 3.58 ηs (Seasonal heat. eff.) % 140 Seasonal space heating eff. class A++ (Range A+++ to D) Prated at -10°C kW 12.5 Average climate water outlet 35°C General SCOP 4.79 4.82 4.95 4.98 ηs (Seasonal heat. eff.) % 188 190 195 196 Seasonal space heating eff. class A+++ (Range A+++ to D) Prated at -10°C kW 8.3 Indoor Unit ELBX 12E6V/9W Casing Material Resin, sheet metal Dimensions Unit HeightxWidthxDepth mm 840x440x390 Weight Unit kg 48.5 Operation range Indoor installation Ambient Min.~Max. °CDB 5~35 Heating Water side Min.~Max. °C 15(6)~65(6)/20(6)~65(6) Domestic hot water Water side Min.~Max. °C 25(6)-62(6) Sound power level Nom. dBA 44.0(4) Sound pressure level Nom. dBA 30.0(5) Water circuit Piping connections diameter inch G 1" (female) Pump Type Grundfos UPM4L K 15-75 130 9 DKI Outdoor Unit ERRA 08EV37 10EV37 12EV37 08EW17 10EW17 12EW17 Dimensions Unit HeightxWidthxDepth mm 1,003x1,270x533 Weight Unit kg 107 Compressor Quantity 1 Type Hermetically sealed swing compressor Operation range Heating/Cooling Min.~Max. °CDB -25.0~25/10~43 Domestic hot water Min.~Max. °CDB -25~35 Refrigerant Type/GWP R-32/675.0 Charge kg/tCO₂eq 3.25/2.19 Control Expansion valve Sound power level Heating/Cooling Nom./Nom. dBA 56.0(7)/60.1(8) 56.0(7)/60.6(8) 56.0(7)/61.5(8) 56.0(7)/61.2(8) 56.0(7)/61.4(8) 56.0(7)/60.9(8) Sound pressure level Heating/Cooling Nom./Nom. dBA 40.6(9)/47.0(10) 40.6(9)/47.4(10) 40.6(9)/48.5(10) 41.1(9)/47.1(10) 41.1(9)/47.2(10) Night quiet mode Heating/Cooling dBA 43.2(9)/43.7(10) 43.2(9)/44.0(10) Piping connections Gas/Liquid OD mm 15.9/6.35 Piping length OU - IU Max. m 50 Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3~/50/400 Current Recommended fuses A 32 16 (1)Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C | (2)Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (3)Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 | (4)Measured with a pressure drop of 10kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/ WB 7°C/6°. | (5)Sound values are measured in a semi-anechoic room. Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings. | (6)For more details, see operation range drawing | (7)Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (8)Condition 2: cooling Ta 35°C - LWE 7°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | (9)Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to the sound level drawings. | (10)The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information
RkJQdWJsaXNoZXIy MTE0MTkzMg==