03_ECPEN27-500_Heating

147 EBVX-D6V ERLA11-16DV38/W18 BRC1HHDK(7) 60°C up to +++ D A+++ + F A+ Voice control Onecta app Guaranteed operation down to -25°C EBVX-D6V/9W + ERLA-DV38/W18 Daikin Altherma 3 R F Floor standing air‑to‑water heat pump for heating, cooling and hot water J Small installation footprint, similar to other household appliances J A combined stainless steel domestic hot water tank of 180 or 230L and heat pump for easy installation J PCB board and hydraulic components are located in the front for easy access J WLAN module and cartridge compatible J Integrated back-up heater choice of 6, 9kW as well as back-up heater less models are available EBVX-D6V EBVX-D9W 011-1W0495 011-1W0496 011-1W0497 011-1W0498 011-1W0499 011-1W0500 Efficiency data EBVX + ERLA 11S18/23D6V/9W + 11DV38 16S18/23D6V/9W + 14DV38 16S18/23D6V/9W + 16DV38 11S18/23D6V/9W + 11DW18 16S18/23D6V/9W + 14DW18 16S18/23D6V/9W + 16DW18 Heating capacity/ Power input A -7°C/W 35°C Max. kW 9.02/3.02 9.29/3.19 10.84/4.06 9.02/3.02 9.29/3.19 10.84/4.06 A -7°C/W 55°C Max. kW 7.97/4.29 8.56/4.61 9.97/5.53 7.97/4.29 8.56/4.61 9.97/5.53 A -7°C/W 60°C Max. kW 7.74/4.51 7.75/4.6 7.77/4.71 7.74/4.51 7.75/4.6 7.77/4.71 A -2°C/W 35°C Max. kW 9.43/2.83 10.21/3.15 11.44/3.81 9.43/2.83 10.21/3.15 11.44/3.81 A 2°C/W 35°C Max. kW 9.76/2.68 10.95/3.12 11.92/3.61 9.76/2.68 10.95/3.12 11.92/3.61 A 7°C/W 35°C Max. kW 12.44/0 13.38/2.83 15.96/3.45 12.44/0 13.38/2.83 15.96/3.45 A 7°C/W 45°C Max. kW 10.98/3.05 12.58/3.39 15.75/4.59 10.98/3.05 12.58/3.39 15.75/4.59 A 7°C/W 55°C Max. kW 10.74/3.59 11.99/4.07 15.7/5.42 10.74/3.59 11.99/4.07 15.7/5.42 Heating capacity Nom. kW 10.6 12.0 16.0 10.6 12.0 16.0 Power input Heating kW 2.18 2.46 3.53 2.18 2.46 3.53 Space heating Average climate water outlet 55°C General SCOP 3.19 3.21 3.26 3.19 3.21 3.26 ηs (Seasonal heat. eff.) % 125 125 127 125 125 127 Seasonal space heating eff. class A++ (Range A+++ to D) Prated at -10°C kW 13 Average climate water outlet 35°C General SCOP 4.63 4.60 4.61 4.72 4.68 ηs (Seasonal heat. eff.) % 182 181 186 184 Seasonal space heating eff. class A+++ (Range A+++ to D) Prated at -10°C kW 10 11 12 10 11 12 Domestic hot water heating General Declared load profile L Average climate COPdhw 2.73/2.63 ηwh (water heating efficiency) % 116/109 Water heating energy efficiency class A+ (Range A+ to F)/ A (Range A+ to F) Indoor Unit EBVX 11S18/23D6V/9W 16S18/23D6V/9W 16S18/23D6V/9W 11S18/23D6V/9W 16S18/23D6V/9W 16S18/23D6V/9W Casing Colour White + Black Material Precoated sheet metal Dimensions Unit HeightxWidthxDepth mm 1,655x595x634/1,855x595x634 Weight Unit kg 124/133 Tank Water volume l 180/230 Maximum water temperature °C 70.0 Maximum water pressure bar 10 Corrosion protection Pickling Operation range Indoor installation Ambient Min.~Max. °CDB -25~35 Heating Water side Min.~Max. °CDB 15~65 Domestic hot water Water side Min.~Max. °CDB 10~60 Sound power level Nom. dBA 44.0 Sound pressure level Nom. dBA 30.0 Outdoor Unit ERLA 11DV38 14DV38 16DV38 11DW18 14DW18 16DW18 Dimensions Unit HeightxWidthxDepth mm 870x1,100x460 Weight Unit kg 101 Compressor Quantity 1 Type Hermetically sealed swing inverter compressor Operation range Heating/Cooling Min.~Max. °CDB -25.0~35/10~43 Domestic hot water Min.~Max. °CDB -25~35 Refrigerant Type/GWP R-32/675.0 Charge kg 3.80 Charge tCO₂eq 2.57 Control Electronic expansion valve Sound power level Heating Nom. dBA 62.0 (1) Sound pressure level Heating Nom. dBA 48.0 (1) Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230 W1/3~/50/400 Current Recommended fuses A 32 16 (1)Measured with a pressure drop of 10kPa in the heating system at an operating condition of leaving water 47-55°C in a room with an ambient of 20°C. DB/WB 7°C/6°. | (2)For more details, see operation range drawing | Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB | Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB | According to EN14825 | Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | Condition 2: cooling Ta 35°C - LWE 7°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) | Operation area is extended to lower flow rates depending on operation mode - refer to ESP curve. | Based on a dT of 45 K | Including piping + PHE + back-up heater; excluding expansion vessel | 4 pole 20A curve 400V tripping class C (refer to wiring diagram)

RkJQdWJsaXNoZXIy MTE0MTkzMg==