03_ECPEN27-500_Heating

215 Another purpose for Daikin high capacity heat pumps Centralised solutions Centralised applications integrate a central source of energy for heating and hot water. Cascade solution is a type of centralised system in which one outdoor unit supplies energy to multiple apartments. Each apartment still includes an indoor unit as control center. In a cascade solution, one larger capacity outdoor unit provides energy to multiple apartments. This larger outdoor unit ranges from 11 to 18kW class, compared to individual heat pumps up to 8kW. Each outdoor unit is connected to the other in order to form a central source of energy that it suitable for a total of up to 50kW. Specific rules apply for the installation of such a system. Applicable units Daikin Altherma 3 H HT + wall mounted indoor unit Daikin Altherma 3 R + wall mounted indoor unit Daikin Altherma 3 M monobloc Hydrosplit connection With Daikin Altherma 3 H HT, you only get water connections to install the outdoor and the indoor units. The unit is available in class 14, 16 and 18kW and delivers a LWT up to 70°C, fitting with radiators. Cascade controller Daikin provides a universal centralised controller for cascade EKKCC9-W to be used in combination with the gateway DCOM-LT/IO. Monobloc Daikin Altherma 3 M also runs LWT under 60°C. The monobloc has the extra advantage to save space inside: indeed no indoor unit is necessary if the domestic hot water tank is installed in the communal space. Refrigerant connection Daikin Altherma 3 R refrigerant split unit is available in class 11, 14 and 16 and delivers a LWT under 60°C.