Sky Air product catalogue

183 FHA71A9 4-M8~M10 103 220 175 15 19 90 90 120 92 175 40 60 51 115 134 59 63 157 63 1230 260 210.6 1270 5 197 690 57 13 1 6 4 5 2 9 12 91 131 197 57 Ø45 14 4 5 11 6 83 105 156 214 221 268 76 268 235 102 105 156 131 57 210 30 100 87 163 189 195 35 8 10 16 18 17 20 116 7 3 180 5 Detailed technical drawings FHA60A9 3D106552 3D109222A Connection position of fresh air intake kit Connection position of fresh air intake kit Position of knockout hole for piping intake (rear) Position of knockout hole for piping intake (rear) Standard location of holes in the wall Standard location of holes in the wall Suspension bolt pitch Suspension bolt pitch Suspension bolt Suspension bolt Front side Front side Suction-side obstacle Piping connection LEFT Floor Suction-side obstacle Rear view Rear view Rear view Rear view Piping intake (rear) Piping intake (rear) Ø100 Knockout hole. Ø100 Knockout hole. 30 or more 30 or more Brand name label Brand name label Note 2 Note 2 Drain pipe connection Drain pipe connection 30 or more 300 or more 30 or more 2,500 or more 2,500 or more Required space Required space Required space Required space Required space Required space Suspension bolt pitch Suspension bolt pitch Service space Service space Service space Service space NOTES 1. Location of nameplate Bottom of the fan housing inside the suction grille 2. When installing a wireless controller, there will be a receiver on this location. For details, see the drawing of the wireless controller. 3. Do not place any objects under the indoor unit. In case of high humidity (>80%), clogged drain outlets, or dirty air filters, condensate may drop out. NOTES 1. Location of nameplate Bottom of the fan housing inside the suction grille 2. When installing a wireless controller, there will be a receiver on this location. For details, see the drawing of the wireless controller. 3. Do not place any objects under the indoor unit. In case of high humidity (>80%), clogged drain outlets, or dirty air filters, condensate may drop out. Number Name Description 1 Air discharge grille 2 Air suction grille 3 Air filter 4 Gas pipe Ø12.7 flare 5 Liquid pipe Ø6.4 flare 6 Drain pipe connection VP20 7 Terminal block with earth terminal Located inside of the unit M4 8 Metal hanger 9 Position of knockout hole Rear side 10 Position of knockout hole Top 11 Piping intake (right) Knockout hole 12 Drain piping intake (left-rear) Knockout hole 13 Drain piping intake (left) Knockout hole 14 Drain piping intake (right) Knockout hole 15 Standard location of holes in the wall Piping intake (rear) Ø100 16 Drain piping intake (top) Ø60 17 Gas piping intake (top) Ø36 18 Liquid piping intake (top) Ø26 19 Power supply wiring and control wiring intake (rear) Ø29 20 Power supply wiring and control wiring intake (top) Ø29 Number Name Description 1 Air discharge grille 2 Air suction grille 3 Air filter 4 Gas pipe Ø15.9 flare 5 Liquid pipe Ø9.5 flare 6 Drain pipe connection VP20 7 Terminal block with earth terminal Located inside of the unit M4 8 Metal hanger 9 Position of knockout hole Rear side 10 Position of knockout hole Top 11 Piping intake (right) Knockout hole 12 Drain piping intake (left-rear) Knockout hole 13 Drain piping intake (left) Knockout hole 14 Drain piping intake (right) Knockout hole 15 Standard location of holes in the wall Piping intake (rear) Ø100 16 Drain piping intake (top) Ø60 17 Gas piping intake (top) Ø36 18 Liquid piping intake (top) Ø26 19 Power supply wiring and control wiring intake (rear) Ø29 20 Power supply wiring and control wiring intake (top) Ø29 300 or more Floor Piping connection LEFT Click here to view all FHA-A(9) technical drawings on my.daikin.eu

RkJQdWJsaXNoZXIy MTE0MTkzMg==