Sky Air product catalogue

226 Unit combination restrictions Power supply Compressor OFM IFM Outdoor unit Indoor unit Hz Voltage Voltage range MCA MFA RHz RLA kW FLA kW FLA RXM25A5V1B9 FDXM25F3V1B9 50 220 Maximum ·50·Hz ·264·V Minimum ·50·Hz ·198·V 40.43 13 42 2.8 0.048 0.59 0.089 0.64 50 230 2.7 50 240 2.6 RXM25A5V1B9 FFA25A2VEB9 50 220 Maximum ·50·Hz ·264·V Minimum ·50·Hz ·198·V 10.14 13 40 2.5 0.048 0.59 0.052 0.38 50 230 2.4 50 240 2.3 RXM25A5V1B9 FNA25A2VEB9 50 220 Maximum ·50·Hz ·264·V Minimum ·50·Hz ·198·V 10.49 13 46 3.1 0.050 0.60 0.094 0.68 50 230 3.0 50 240 2.9 RXM35A5V1B9 FBA35A2VEB9 50 220 Maximum ·50·Hz ·264·V Minimum ·50·Hz ·198·V 11.73 13 55 3.7 0.050 0.60 0.250 1.81 50 230 3.5 50 240 3.4 RXM35A5V1B9 FCAG35BVEB 50 220 Maximum ·50·Hz ·264·V Minimum ·50·Hz ·198·V 10.23 13 58 3.6 0.050 0.60 0.062 0.45 50 230 3.4 50 240 3.3 RXM35A5V1B9 FDXM35F3V1B9 50 220 Maximum ·50·Hz ·264·V Minimum ·50·Hz ·198·V 10.45 13 70 4.5 0.050 0.60 0.089 0.64 50 230 4.3 50 240 4.1 RXM35A5V1B9 FFA35A2VEB9 50 220 Maximum ·50·Hz ·264·V Minimum ·50·Hz ·198·V 10.15 13 58 3.6 0.050 0.60 0.052 0.38 50 230 3.4 50 240 3.3 RXM35A5V1B9 FHA35AVEB98 50 220 Maximum ·50·Hz ·264·V Minimum ·50·Hz ·198·V 10.68 13 58 3.7 0.050 0.60 0.118 0.85 50 230 3.5 50 240 3.4 RXM35A5V1B9 FNA35A2VEB9 50 220 Maximum ·50·Hz ·264·V Minimum ·50·Hz ·198·V 10.49 13 70 4.5 0.050 0.60 0.094 0.68 50 230 4.3 50 240 4.1 ARXM35A5V1B9 ADEA35A2VEB 50 220 Maximum ·50·Hz ·264·V Minimum ·50·Hz ·198·V 11.73 13 55 3.7 0.050 0.60 0.250 1.81 50 230 3.5 50 240 3.4 RXM25A5V1B9 FVXM25A3V1B FVXM25A3V1B9 50 220 Maximum ·50·Hz ·264·V Minimum ·50·Hz ·198·V 9.92 13 38 2.6 0.052 0.63 0.037 0.14 50 230 2.5 50 240 2.4 RXM25A5V1B9 FVXM25B2V1B 50 220 Maximum ·50·Hz ·264·V Minimum ·50·Hz ·198·V 9.92 13 38 2.7 0.052 0.63 0.037 0.14 50 230 2.6 50 240 2.5 RXM35A5V1B9 FVXM35A3V1B FVXM35A3V1B9 50 220 Maximum ·50·Hz ·264·V Minimum ·50·Hz ·198·V 9.92 13 58 3.9 0.052 0.63 0.037 0.14 50 230 3.8 50 240 3.6 RXM35A5V1B9 FVXM35B2V1B 50 220 Maximum ·50·Hz ·264·V Minimum ·50·Hz ·198·V 9.92 13 58 4.1 0.052 0.63 0.037 0.14 50 230 3.9 50 240 3.7 Symbols Notes MCA MFA RLA OFM IFM FLA kW RHz Minimum Circuit Ampere Maximum Fuse Ampere Rated load amps Outdoor fan motor Indoor fan motor Full Load Ampere Fan motor rated output Rated operating frequency [A] [A] [A] [A] [kW] [Hz] 1 The RLA is based on the following conditions. Outdoor temperature 35°C DB Indoor temperature 27°C DB / 19°C WB 2 Select the wire size according to the MCA. 3 The maximum allowable voltage that is unbalanced between phases is 2%. 4 Use a circuit breaker instead of a fuse. 4D152147A Detailed technical drawings RXM25-35R9 / ARXM35R9 Click here to view all RXM-A9 technical drawings on my.daikin.eu Click here to view all ARXM-A9 technical drawings on my.daikin.eu

RkJQdWJsaXNoZXIy MTE0MTkzMg==