VRV product catalogue

175 D C B A 1 1 2 2 3 3 5 1 3 630 9 8 6 9 6 6 135 135 2 9 2 9 1 16 600 1 6 2 845 122 346 1 3 0 2 3 0 13 9 10 10 11 12 120 300 P100 X 3 = 180 300 P100 X 3 = 14 10 10 A 4 6 7 8 5 15 305 1 6 2 2 4 4 305 197 154 122 2 4 4 15 Item Name Description 1 2 3 4 5 6 7 8 9 1 11 Suspension bracket Drain socket Inspection hole 12 VP20 (OD Ø26, ID Ø20) 13 Ø ·22.2· brazing connection Ø ·15.9· brazing connection Ø ·12.7· brazing connection Ø ·15.9· brazing connection Ø ·6.35· brazing connection Ø ·9.52· brazing connection Ø ·9.52· brazing connection M8~M10 14 15 Damper Duct connection kit Control box Diameter ·Ø160· Diameter ·Ø160· Outdoor unit suction gas pipe connection port Outdoor unit HP/LP gas pipe connection port Indoor unit gas pipe connection port Outdoor unit liquid pipe connection port Indoor unit liquid pipe connection port Duct connection Indoor unit gas pipe connection port Indoor unit gas pipe connection port Indoor unit liquid pipe connection port Ø ·22.2· brazing connection 40 5 3D139835 BS4A14AV1B 2 9 1 16 1000 6 9 6 6 1 3 0 2 3 0 845 122 346 2 9 1 6 2 F E D C B A 1 1 2 2 3 3 220 500 P100 X 5 = 280 500 P100 X 5 = 5 1 3 1030 9 8 135 135 13 14 4 6 7 8 9 10 10 11 12 5 10 10 A 15 305 1 6 2 2 4 4 305 197 154 122 2 4 4 15 Item Name Description 1 2 3 4 5 6 7 8 9 1 11 Suspension bracket Drain socket Inspection hole 12 VP20 (OD Ø26, ID Ø20) 13 Ø ·22.2· brazing connection Ø ·15.9· brazing connection Ø ·12.7· brazing connection Ø ·15.9· brazing connection Ø ·6.35· brazing connection Ø ·9.52· brazing connection Ø ·9.52· brazing connection M8~M10 14 15 Damper Duct connection kit Control box Diameter ·Ø160· Diameter ·Ø160· Outdoor unit suction gas pipe connection port Outdoor unit HP/LP gas pipe connection port Indoor unit gas pipe connection port Outdoor unit liquid pipe connection port Indoor unit liquid pipe connection port Duct connection Indoor unit gas pipe connection port Indoor unit gas pipe connection port Indoor unit liquid pipe connection port Ø ·22.2· brazing connection 40 5 3D139836 BS6A14AV1B 3D139835 3D139836 Detailed technical drawings BS4A14AV1B9 BS6A14AV1B9 Item Name Description 1 Outdoor unit suction gas pipe connection port Ø ·22.2· brazing connection 2 Outdoor unit HP/LP gas pipe connection port Ø ·22.2· brazing connection 3 Outdoor unit liquid pipe connection port Ø ·15.9· brazing connection 4 Indoor unit gas pipe connection port Ø ·9.52· brazing connection 5 Indoor unit gas pipe connection port Ø ·12.7· brazing connection 6 Indoor unit gas pipe connection port Ø ·15.9· brazing connection 7 Indoor unit liquid pipe connection port Ø ·6.35· brazing connection 8 Indoor unit liquid pipe connection port Ø ·9.52· brazing connection 9 Control box 10 Suspension bracket M8~M10 11 Drain socket VP20 (OD Ø26, ID Ø20) 12 Inspection hole 13 Duct connection Diameter ·Ø160· 14 Damper 15 Duct connection kit Diameter ·Ø160· Item Name Description 1 Outdoor unit suction gas pipe connection port Ø ·22.2· brazing connection 2 Outdoor unit HP/LP gas pipe connection port Ø ·22.2· brazing connection 3 Outdoor unit liquid pipe connection port Ø ·15.9· brazing connection 4 Indoor unit gas pipe connection port Ø ·9.52· brazing connection 5 Indoor unit gas pipe connection port Ø ·12.7· brazing connection 6 Indoor unit gas pipe connection port Ø ·15.9· brazing connection 7 Indoor unit liquid pipe connection port Ø ·6.35· brazing connection 8 Indoor unit liquid pipe connection port Ø ·9.52· brazing connection 9 Control box 10 Suspension bracket M8~M10 11 Drain socket VP20 (OD Ø26, ID Ø20) 12 Inspection hole 13 Duct connection Diameter ·Ø160· 14 Damper 15 Duct connection kit Diameter ·Ø160· Option kit EKBSDCK Option kit EKBSDCK Detail ·A· Detail ·A· Click here to view all BS-A14AV1B9 technical drawings on my.daikin.eu

RkJQdWJsaXNoZXIy MTE0MTkzMg==