VRV product catalogue

176 2 9 1 16 1000 9 8 6 9 6 6 135 135 1 3 0 2 3 0 845 122 346 2 9 1 6 2 H G F E D C B A 120 700 P100 X 7 = 180 700 P100 X 7 = Item Name Description 1 2 3 4 5 6 7 8 9 1 11 Suspension bracket Drain socket Inspection hole 12 VP20 (OD Ø26, ID Ø20) 13 Ø ·22.2· brazing connection Ø ·15.9· brazing connection Ø ·12.7· brazing connection Ø ·15.9· brazing connection Ø ·6.35· brazing connection Ø ·9.52· brazing connection Ø ·9.52· brazing connection M8~M10 1 1 2 2 3 3 15 14 15 Damper Duct connection kit 13 14 4 6 7 8 9 10 10 11 12 5 A 5 1 3 1030 10 10 Control box Diameter ·Ø160· Diameter ·Ø160· 2 4 4 305 154 197 305 1 6 2 Outdoor unit suction gas pipe connection port Outdoor unit HP/LP gas pipe connection port Indoor unit gas pipe connection port Outdoor unit liquid pipe connection port Indoor unit liquid pipe connection port Duct connection Indoor unit gas pipe connection port Indoor unit gas pipe connection port Indoor unit liquid pipe connection port Ø ·22.2· brazing connection 122 2 4 4 15 40 5 3D139837 BS8A14AV1B Option kit EKBSDCK Detail ·A· JIHGFEDCBA 1 1 2 2 3 3 5 1 3 13 9 10 10 11 12 14 10 10 4 6 7 8 5 A 1430 15 305 1 6 2 2 4 4 6 9 9 8 6 6 135 2 9 2 9 1 135 1400 16 1 6 2 305 845 122 346 154 197 220 280 900 P100 X 9 = 900 P100 X 9 = 122 2 4 0 15 Item Name Description 1 2 3 4 5 6 7 8 9 1 11 Suspension bracket Drain socket Inspection hole 12 VP20 (OD Ø26, ID Ø20) 13 Ø ·22.2· brazing connection Ø ·15.9· brazing connection Ø ·12.7· brazing connection Ø ·15.9· brazing connection Ø ·6.35· brazing connection Ø ·9.52· brazing connection Ø ·9.52· brazing connection M8~M10 14 15 Damper Duct connection kit Control box Diameter ·Ø160· Diameter ·Ø160· Outdoor unit suction gas pipe connection port Outdoor unit HP/LP gas pipe connection port Indoor unit gas pipe connection port Outdoor unit liquid pipe connection port Indoor unit liquid pipe connection port Duct connection Indoor unit gas pipe connection port Indoor unit gas pipe connection port Indoor unit liquid pipe connection port Ø ·22.2· brazing connection 40 5 1 3 0 2 3 0 3D139838 BS10A14AV1B 3D139837 Detailed technical drawings BS8A14AV1B9 Item Name Description 1 Outdoor unit suction gas pipe connection port Ø ·22.2· brazing connection 2 Outdoor unit HP/LP gas pipe connection port Ø ·22.2· brazing connection 3 Outdoor unit liquid pipe connection port Ø ·15.9· brazing connection 4 Indoor unit gas pipe connection port Ø ·9.52· brazing connection 5 Indoor unit gas pipe connection port Ø ·12.7· brazing connection 6 Indoor unit gas pipe connection port Ø ·15.9· brazing connection 7 Indoor unit liquid pipe connection port Ø ·6.35· brazing connection 8 Indoor unit liquid pipe connection port Ø ·9.52· brazing connection 9 Control box 10 Suspension bracket M8~M10 11 Drain socket VP20 (OD Ø26, ID Ø20) 12 Inspection hole 13 Duct connection Diameter ·Ø160· 14 Damper 15 Duct connection kit Diameter ·Ø160· 3D139838 BS10A14AV1B9 Item Name Description 1 Outdoor unit suction gas pipe connection port Ø ·22.2· brazing connection 2 Outdoor unit HP/LP gas pipe connection port Ø ·22.2· brazing connection 3 Outdoor unit liquid pipe connection port Ø ·15.9· brazing connection 4 Indoor unit gas pipe connection port Ø ·9.52· brazing connection 5 Indoor unit gas pipe connection port Ø ·12.7· brazing connection 6 Indoor unit gas pipe connection port Ø ·15.9· brazing connection 7 Indoor unit liquid pipe connection port Ø ·6.35· brazing connection 8 Indoor unit liquid pipe connection port Ø ·9.52· brazing connection 9 Control box 10 Suspension bracket M8~M10 11 Drain socket VP20 (OD Ø26, ID Ø20) 12 Inspection hole 13 Duct connection Diameter ·Ø160· 14 Damper 15 Duct connection kit Diameter ·Ø160· Option kit EKBSDCK Detail ·A· Click here to view all BS-A14AV1B9 technical drawings on my.daikin.eu

RkJQdWJsaXNoZXIy MTE0MTkzMg==