VRV product catalogue

191 328 328 427 427 448 508 840 840 55 55 A 1 2 3 4 5 6 0 140 130 120 110 100 90 80 70 60 50 40 30 20 10 725 (1000) 455 O148 180 278 AA O148 AB 320 222 455 FXFA-A WITH DESIGNER PANEL FXFA-A WITH FRESH AIR INTAKE 2D121703D 3D121741C NOTES 1. When installing a fresh air intake kit, provide a service access panel. 2. Field construction 3. This corner discharge outlet needs to be closed. 4. When installing a duct fan, use a wiring adapter to link the duct fan to the fan of the indoor unit. 5. The intake air flow rate is recommended to be ≤20% of the air flow rate at high fan speed. If the intake air flow rate is too large, the operating sound may increase, and the detection of the indoor unit suction temperature may be affected. 6. This indicates the distance between the T-joint inlet and the indoor unit inlet when the T-tube is connected. Model AA AB FCAG35/50/60/71BVEB 277 319 FXFQ20/25/32/40/50/63BVEB FXFA20/25/32/40/50/63A2VEB FCAG100/125/140BVEB 319 361 FXFQ80/100BVEB FXFA80/100A2VEB FXFN50/71A2VEB FCAHG71/100/125/140HVEB 361 403 FXFQ125BVEB FXFA125A2VEB FXFN112A2VEB ARROW VIEW C View ·A· Duct Piping side Drain side See note ·3· Inlet T-joint Designer decoration panel Decoration panel Suction chamber Suction chamber Field supply See note ·6· Ceiling opening Ceiling opening Air flow rate [m³/min] Static pressure in chamber [Pa] See note ·3· Service access panel ·450 x 450 mm· or more Duct Left side Right side See note ·1·. 35 35 1 7 2 C 5 ARROW VIEW C 340 0 - 6 7 5 M M10 1 2 4 3 950 9 5 0 8 7 6 AB 2 1 3 O75 10 DETAIL A 7 8 0 710 420 9 420 DETAIL B 121.5 350 9 5 5 4 . 5 5 4 . 5 81 100 100 85 9 6 . 5 DETAIL B 350 121.5 DETAIL A 81 100 100 85 8 0 1 0 0 1 0 0 8 0 54.554.5 96.5 2 5 . 4 1 2 1 . 5 3 5 0 95 67 53 1 2 1 . 5 2 5 . 4 3 5 0 8 0 1 0 0 1 0 0 8 0 96.5 9 6 . 5 6 7 5 3 Suspension position Ceiling opening See note ·3·. See note ·5·. See note ·6·. Drain side Piping side Opposite side ·2· places Opposite side ·2· places FCAG35/50/60/71BVEB FXFQ20/25/32/40/50/63BVEB FXFA20/25/32/40/50/63A2VEB FCAG100/125/140BVEB FCAHG71/100/125/140HVEB FXFQ80/100/125BVEB FXFA80/100/125A2VEB FCAG100/125/140BVEB FCAHG71/100/125/140HVEB FXFQ80/100/125BVEB FXFA80/100/125A2VEB FCAG35/50/60/71BVEB FXFQ20/25/32/40/50/63BVEB FXFA20/25/32/40/50/63A2VEB Opposite side ·2· places Opposite side ·2· places Adjustable Suspension bolt OR A B 860 910 8 6 0 - 9 1 0 1 5 2 1 9 2 280 330 A A 55 840 55 840 ( ) ·1500· or more or more more m Item Gas pipe connection port Liquid pipe connection port Drain pipe connection Drain hose Knockout hole. Power supply wiring intake Transmission wiring intake hole Air discharge outlet Corner decoration cover Name 10 9 8 7 6 5 4 3 2 1 Flat grille assembly Fixation holes Installation box for adaptor PCB Only in case of ·FXFA· models A C ARROW VIEW C Installation box for adaptor PCB Only in case of ·FXFA· models FCAG35/50/60/71BVEB FXFQ20/25/32/40/50/63BVEB FCAG100/125/140BVEB, FCAHG71/100/125/140HVEB FXFQ80/100/125BVEB, FXFA80/100/125A2VEB 2D121703D DETAIL B ·2· places Opposite side DETAIL A ·2· places Opposite side FCAG100/125/140BVEB FCAHG71/100/125/140HVEB FXFQ80/100/125BVEB FXFA80/100/125A2VEB FCAG35/50/60/71BVEB FXFQ20/25/32/40/50/63BVEB FXFA20/25/32/40/50/63A2VEB FCAG35/50/60/71BVEB FXFQ20/25/32/40/50/63BVEB FXFA20/25/32/40/50/63A2VEB FCAG100/125/140BVEB FCAHG71/100/125/140HVEB FXFQ80/100/125BVEB FXFA80/100/125A2VEB ARROW VIEW C FCAG35/50/60/71BVEB FXFQ20/25/32/40/50/63BVEB FXFA20/25/32/40/50/63A2VEB ARROW VIEW C FCAG100/125/140BVEB, FCAHG71/100/125/140HVEB FXFQ80/100/125BVEB, FXFA80/100/125A2VEB DETAIL A ·2· places Opposite side DETAIL B ·2· places Opposite side ·300· or less Suspension position Suspension position 4 - M8 or M10 Ceiling-mounted lighting Air fan Other unit Fixation holes Fixation holes ·1,500· or more ·1,500· or more ·1,500· or more ·1,500· or more ·200· or more ·200· or more only in case of ·FXFA· models Installation box for adaptor PCB only in case of ·FXFA· models Suspension position Ceiling opening See note ·3·. Respect the distances shown on the figure. See note ·3·. See note ·3·. ·1,500· or more Piping side Drain side ·2,000· or more ·4,000· or more See note ·5·. Ceiling opening See note ·3·. Adjustable ·AD· or more 217 52 Required installation space Required installation space If a discharge outlet is closed up with the “sealing member”option kit, then the required installation space on that (closed up) side is ·500·mm instead of ·1,500·mm. Cassette height Minimal installation height Required installation space AA AB AC AD Model 204 139 269 2,700 FCAG35/50/60/71BVEB 246 180 311 2,700 FCAG100/125/140BVEB 288 180 353 2,700 FCAHG71/100/125/140HVEB 204 139 269 2,700 FXFQ20/25/32/40/50/63BVEB 246 180 311 2,700 FXFQ80/100BVEB 288 180 353 2,700 FXFQ125BVEB 204 139 269 2,500 FXFA20/25/32/40/50/63A2VEB 246 180 311 2,500 FXFA80/100A2VEB 288 180 353 2,500 FXFA125A2VEB Item Name 1 Liquid pipe connection port 2 Gas pipe connection port 3 Drain pipe connection 4 Power supply wiring intake 5 Transmission wiring intake hole 6 Air discharge outlet 7 Flat grille assembly 8 Corner decoration cove 9 Drain hose 10 Knockout hole NOTES 1. Location of nameplate: The unit nameplate is located on the control box cover. The decoration panel nameplate is located on the piping-side panel frame, under the corner cover. 2. When installing optional accessories, refer to their respective documentation. 3. Make sure the distance between the ceiling and the cassette does not exceed ·35·mm. The maximum ceiling opening is ·910·mm. 4. When the conditions in the ceiling exceed 30°C ambient temperature and 80% relative humidity, or when fresh air is inducted into the ceiling, additional insulation is required (polyethylene foam, thickness ≥·10·mm). 5. When installing a sensor kit, there will be a sensor on this location. For details, see the drawing of the sensor kit. 6. When installing a wireless controller, there will be a receiver on this location. For details, see the drawing of the wireless controller. See note ·6·. Detailed technical drawings Click here to view all FXFA-A technical drawings on my.daikin.eu

RkJQdWJsaXNoZXIy MTE0MTkzMg==