192 1 5 0 8 9 89 223 O100 4 1 9 0 575 22 A 8 533( 5 3 3 ( ) 5 5 5 5( 5 9 5 5 8 5 ~ ( ) B 320 3 5 320 172 21 63 22 575 22 196 2 0 1 5 6 1 9 4 2 9 8 2 6 0 4 6 ( 0 ~ 6 7 5 ) 8 5 0 3 1 2 8 C BYFQ60C4W1W BYFQ60C4W1 590 620 6 2 0 7 6 5 1 5 0 8 9 89 210 O100 4 A 8 533 ( 5 3 3 ( B 172 21 63 575 196 1 4 5 1 8 3 2 8 5 2 6 0 ( 0 ~ 8 5 0 3 1 2 C 320 585 660 6 6 0 5 8 5 ~ ( 320 3 5 62 5 575 62 5 2 0 5 5 5 62 5 62 5 2 5 3 0 590 7 6 5 700 7 0 0 3 1 c sp e e 0 n a e a 2 4 5 6 7 3 8 · FXZA-A NEW PANEL FXZA-A OLD PANEL 3D125141A 3D125613A NOTES 1. Location of nameplate The indoor unit nameplate is located on the bell mouth inside the suction grille. The decoration panel nameplate is located on the inner frame inside the suction grille. 2. When installing a wireless controller, there will be a receiver on this location. For details, see the drawing of the wireless controller. 3. If any of the following conditions are met, additional insulation (glass wool or polyethylene foam, thickness ≥·10·mm) is required: Ambient conditions in the ceiling ≥ ·30·°C and ·80·% relative humidity. Fresh air is inducted into the ceiling. The unit operates continuously. 4. Though the installation is acceptable up to maximum ·595·mm square ceiling opening, keep the clearance of ·10·mm or less between the indoor unit and the ceiling opening, so that the panel overlap allowance can be ensured. NOTES 1. Location of nameplate The indoor unit nameplate is located on the bell mouth inside the suction grille. The decoration panel nameplate is located on the inner frame inside the suction grille. 2. When installing a wireless controller, there will be a receiver on this location. For details, see the drawing of the wireless controller. 3. If any of the following conditions are met, additional insulation (glass wool or polyethylene foam, thickness ≥·10·mm) is required: Ambient conditions in the ceiling ≥ ·30·°C and ·80·% relative humidity. Fresh air is inducted into the ceiling. The unit operates continuously. 4. Though the installation is acceptable up to maximum ·660·mm square ceiling opening, keep the clearance of ·45·mm or less between the indoor unit and the ceiling opening, so that the panel overlap allowance can be ensured. Item Part name 1 Liquid pipe connection ·Ø 6.4· 2 Gas pipe connection ·15-32 ø9.5· Gas pipe connection ·40-50 ø12.7· 3 Drain outlet ·VP20· Outer: ·Ø26· 4 Power supply 5 Remote control wiring intake 6 Air discharge grille 7 Air suction grille 8 Drain hose Inner: ·Ø25· Item Part name 1 Liquid pipe connection ·Ø 6.4· 2 Gas pipe connection ·15-32 ø9.5· Gas pipe connection ·40-50 ø12.7· 3 Drain outlet ·VP20· Outer: ·Ø26· 4 Power supply 5 Remote control wiring intake 6 Air discharge grille 7 Air suction grille 8 Drain hose Inner: ·Ø25· Note ·2 · Note ·2 · Suspension bolt Suspension bolt 4-M8~M10 4-M8~M10 ·10· or less ·45· or less ·308· or more ·295· or more ·1,500· or more Required space ·1,500· or more Required space To floor ·2,700· or more Ceiling height To floor ·2,700· or more Ceiling height ·10· or less ·45· or less Note ·4· Note ·4· View ·A· View ·B· View ·C· View ·C· Piping side Piping side ·300· or less ·300· or less (Ceiling opening) Outdoor air intake (direct connection) Outdoor air intake (direct connection) Required space Required space ·1,500mm· or more ·1,500mm· or more ·1,500mm· or more ·1,500mm· or more When closing the air outlet, the required space is ·200·mm or more. When closing the air outlet, the required space is ·200·mm or more. 4-M 4Hole 4-M 4Hole Service access panel ·450 x 450mm· or more Service access panel ·450 x 450mm· or more Drain side Drain side Adjustable Adjustable (0~675) Decoration panel BYFQ60C4W1W Fresh white ·N9.5· BYFQ60C4W1S Daikin silver Decoration panel BYFQ60B2W1 White RAL 9010 BYFQ60B3W1 White RAL 9010 (Ceiling opening) (Suspension position) (Ceiling opening) (Suspension position) View ·A· View ·B· (Ceiling opening) (Suspension position) (Suspension position) Detailed technical drawings Click here to view all FXZA-A technical drawings on my.daikin.eu
RkJQdWJsaXNoZXIy MTE0MTkzMg==