194 FXKA20,25,32A FXKA40,50,63A Adjusting the air flow direction Adjusting the air flow direction Up/down (automatic) Up/down (automatic) Left/right (automatic) Left/right (automatic) Air discharge range swing Air discharge range swing 150 or more 150 or more 150 or more 150 or more 150 or more 150 or more 1,500 or more 1,500 or more 1,000 or more 1,000 or more 490~510 Ceiling opening 490~510 Ceiling opening 903 Suspension position 1,303 Suspension position Suspension bolt Suspension bolt Knockout hole Knockout hole 850 or less 35 or less 35 or less Adjustable (0~635) Adjustable (0~635) 860~910 Ceiling opening 1,260~1,310 Ceiling opening 371 Suspension position 371 Suspension position See note 2 See note 2 See note 2 See note 2 Required space Required space Detailed technical drawings 2D146914A 2D148806A Model øA øA FXKQ20AMVEB 6.4 12.7 FXKQ25AMVEB 6.4 12.7 FXKQ32AMVEB 6.4 12.7 FXKA20AMVEB 6.4 9.5 FXKA25AMVEB 6.4 9.5 FXKA32AMVEB 6.4 9.5 Model øA øA FXKQ40AMVEB 6.4 12.7 FXKQ50AMVEB 6.4 12.7 FXKQ63AMVEB 6.4 12.7 FXKA40AMVEB 6.4 9.5 FXKA50AMVEB 6.4 9.5 FXKA63AMVEB 6.4 9.5 Item Name 1 Liquid pipe connection øA 2 Gas pipe connection øB 3 Drain outlet Inside diameter: 20mm Outside diameter: 26mm 4 Power supply wiring intake 5 Wiring connection Remote control wiring intake 6 Air discharge side 7 Air suction side 8 Drain hose (accessory) Inside diameter 25mm 9 Metal hanger Item Name 1 Liquid pipe connection øA 2 Gas pipe connection øB 3 Drain outlet Inside diameter: 20mm Outside diameter: 26mm 4 Power supply wiring intake 5 Wiring connection Remote control wiring intake 6 Air discharge side 7 Air suction side 8 Drain hose (accessory) Inside diameter 25mm 9 Metal hanger NOTES 1. Location of unit’s Name plate • The unit nameplat is located on the control box cover. • The decoration panel nameplate is located on the inner frame inside the suction grille 2. Though the installation is acceptable up to maximum 910x510 mm square ceiling opening, keep the clearance of 35 mm or less between the indoor unit and the ceiling opening, so that the panel overlap allowance can be insured. 3. When installing an optional accessories, refer to their respective documentation. 4. If any of the following conditions are met, additional insulation (glass wool or polyethylene foam, thickness ≥ 10mm) is required. • Ambient conditions in the celing ≥ 30°C and 80% relative humidity. • Fresh air is inducted into the ceiling • The unit operates continuously. NOTES 1. Location of unit’s Name plate • The unit nameplat is located on the control box cover. • The decoration panel nameplate is located on the inner frame inside the suction grille 2. Though the installation is acceptable up to maximum 1,310x510 mm square ceiling opening, keep the clearance of 35 mm or less between the indoor unit and the ceiling opening, so that the panel overlap allowance can be insured. 3. When installing an optional accessories, refer to their respective documentation. 4. If any of the following conditions are met, additional insulation (glass wool or polyethylene foam, thickness ≥ 10mm) is required. • Ambient conditions in the celing ≥ 30°C and 80% relative humidity. • Fresh air is inducted into the ceiling • The unit operates continuously. 850 or less 300 or less Click here to view all FXKA-A technical drawings on my.daikin.eu

RkJQdWJsaXNoZXIy MTE0MTkzMg==