VRV product catalogue

193 150 89 89 223 O100 4 190 22 575 22 A 8 533 533 585~595 585~595 B 320 345 320 172 211 63 22 575 22 196 220 156 194 298 38 8 260 46 ADJUSTABLE(0~630) 850 3 1 2 C 590 620 620 7 6 5 3D082052 FXZQ-A NEW PANEL 3D082052 NOTES 1. Sticking location for manufacture's label Manufacture's label for indoor unit: on the bell mouth inside suction grille Manufacture's label for decoration panel: on the inner frame inside suction grille 2. In case of using wireless remote controller,this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail. 3. When the temperature and humidity in the ceiling exceed 30°C and RH 80% or the fresh air is inducted into the ceiling or the unit continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required. 4. Though the installation is acceptable up to maximum of 595mm square ceiling opening, keep the clearance of 10mm or less between the main unit and the ceiling opening so that the panel overlap allowance can be ensured. Item Part name Remark 1 Liquid pipe connection Ø 6.4 (flare connection) 2 Gas pipe connection Ø 12.7 (flare connection) 3 Drain pipe connection VP20 (O.D. Ø26) 4 Power supply connection 5 Remote control code and control wiring connection 6 Air discharge grille 7 Air suction grille 8 Drain hose I.D. Ø25 (outlet) Note 2 Suspension bolt 4-M8~M10 10 or less 300 or more 1,500 or more Required space From the floor side 2,500 or more For height installation 10 or less Note 4 Pipe connection side 300 or less Outdoor air intake (direct connection) Required space 1,500mm or more  1,500mm or more  1,500mm or more  1,500mm or more   When the discharge grill is closeout, the required space is 200mm or more. 4-M 4Hole Service access panel 450 x 450mm or more Drain connection side Adjustable Decoration panel BYFQ60C2W1W Fresh white ·N9.5· BYFQ60C2W1S Daikin silver (Ceiling opening space) (Suspension position) (Ceiling opening) (Suspension position) A Arrow view C Arrow view B Arrow view FXZQ-A OLD PANEL 3D082161D 150 89 89 210 O100 4 (180) A 8 533 533 B 172 211 63 575 196 145 183 285 260 (0~645) 850 3 1 2 4-M8~M10 C 320 585~660 585~660 320 345 62.5 575 62.5 205 55 62.5 62.5 25 30 590 6 7 5 700 700 31 NOTES 1. Location of nameplate The indoor unit nameplate is located on the bell mouth inside the suction grille. The decoration panel nameplate is located on the inner frame inside the suction grille. 2. When installing a wireless controller, there will be a receiver on this location. For details, see the drawing of the wireless controller. 3. If any of the following conditions are met, additional insulation (glass wool or polyethylene foam, thickness ≥·10·mm) is required: Ambient conditions in the ceiling ≥ ·30·°C and ·80·% relative humidity. Fresh air is inducted into the ceiling. The unit operates continuously. 4. Though the installation is acceptable up to maximum ·660·mm square ceiling opening, keep the clearance of ·45·mm or less between the indoor unit and the ceiling opening, so that the panel overlap allowance can be ensured. Item Part name 1 Liquid pipe connection 2 Gas pipe connection 3 Drain outlet ·VP20· Outer: ·Ø26· 4 Power supply 5 Remote control wiring intake 6 Air discharge grille 7 Air suction grille 8 Drain hose Inner: ·Ø25· Note ·2 · Suspension position ·45· or less ·295· or more Required space ·1,500· or more To floor ·2,500· or more ·45· or less Note ·4· Note ·4· View ·A· View ·B· View ·C· Piping side ·300· or less Ceiling opening Outdoor air intake (direct connection) Required space ·1,500mm· or more ·1,500mm· or more When closing the air outlet, the required space is ·200·mm or more. 4-M 4Hole Ceiling opening Suspension position Suspension position Service access panel ·450 x 450mm· or more Drain side Adjustable Decoration panel BYFQ60B2W1 White RAL 9010 BYFQ60B3W1 White RAL 9010 Ceiling height Detailed technical drawings Click here to view all FXZQ-A technical drawings on my.daikin.eu

RkJQdWJsaXNoZXIy MTE0MTkzMg==