VRV product catalogue

220 35 340 0-675 3 950 950 8 7 6 AB 213 780 710 420 9 420 A B 860-910 860-910 10°10° 256 (*3) (*2) (*1) 35 350 121.5 54.5 54.5 96.5 81 100 100 85 95 54.5 54.5 96.5 80 100 100 80 95 350 121.5 25.4 O75 10 840 55 210 55 1 2 4 840 280 330 190 230 AC 255 AA (90) 40 5 FXFN - B SELF CLEANING PANEL FXFN-B WITH STANDARD PANEL 2D156432 2D156545 35 0-675 3 950 950 8 7 6 AB 213 A 780 710 420 9 420 B 55 55 840 340 54.5 54.5 96.5 80 100 100 80 95 350 25.4 121.5 O75 10 860-910 860-910 35 81 100 100 85 95 121.5 350 54.5 54.5 96.5 175 10 40 840 280 330 110 150 AC AA 4 1 2 5 FXFN-B STANDARD PANEL DETAIL B ·2· places Opposite side DETAIL A ·2· places Opposite side FXFN40/50/63B2VEB FXFN80B2VEB FXFN40/50/63B2VEB FXFN80B2VEB View ·C· FXFN40/50/63B2VEB FXFN80B2VEB ·300· or less Suspension position Suspension position 4 - M8 or M10 Ceiling-mounted lighting Air fan Other unit ·1,500· or more ·1,500· or more ·1,500· or more ·1,500· or more ·1,500· or more ·200· or more ·200· or more Suspension position Ceiling opening See note ·3·. Respect the distances shown on the figure. See note ·3·. View ·C· View ·C· See note ·3·. ·1,500· or more Piping side Drain side ·2,000· or more ·4,000· or more See note ·5·. See note ·6·. Ceiling opening See note ·3·. Adjustable ·2,700· or more Required installation space Required installation space If a discharge outlet is closed up with the “sealing member”option kit, then the required installation space on that (closed up) side is ·500·mm instead of ·1,500·mm. NOTES 1. Location of nameplate: The unit nameplate is located on the control box cover. The decoration panel nameplate is located on the piping-side panel frame, under the corner cover. 2. When installing optional accessories, refer to their respective documentation. 3. Make sure the distance between the ceiling and the cassette does not exceed ·35·mm. The maximum ceiling opening is ·910·mm. 4. When the conditions in the ceiling exceed 30°C ambient temperature and 80% relative humidity, or when fresh air is inducted into the ceiling, additional insulation is required (polyethylene foam, thickness ≥·10·mm). 5. When installing a sensor kit, there will be a sensor on this location. For details, see the drawing of the sensor kit. 6. When installing a wireless controller, there will be a receiver on this location. For details, see the drawing of the wireless controller. Item Name 1 Liquid pipe connection port 2 Gas pipe connection port 3 Drain pipe connection 4 Power supply wiring intake 5 Transmission wiring intake hole 6 Air discharge outlet 7 Air suction grille 8 Corner decoration cove 9 Drain hose 10 Knockout hole Cassette height Minimal installation height AA AB AC Model 246 180 269 FXFN40/50/63B2VEB 288 180 311 FXFN80B2VEB Cassette height Minimal installation height AA AB AC Model 246 180 349 FXFN40/50/63B2VEB 288 180 391 FXFN80B2VEB DETAIL A ·2· places Opposite side FXFN40/50/63B2VEB FXFN80B2VEB FXFN40/50/63B2VEB FXFN80B2VEB View ·C· FXFN40/50/63B2VEB FXFN80B2VEB DETAIL B ·2· places Opposite side ·300· or less Suspension position Suspension position Ceiling-mounted lighting Air fan Other unit Piping Piping Air suction grille Dust opening ·1,500· or more ·1,500· or more ·1,500· or more ·1,500· or more ·200· or more ·200· or more Suspension position Ceiling opening See note ·3·. Respect the distances shown on the figure. Installation direction See note ·3·. See note ·3·. ·1,500· or more Piping side Drain side ·2,000· or more ·4,000· or more See note ·5·. Ceiling opening See note ·3·. Adjustable ·2,700· or more Required installation space Required installation space If a discharge outlet is closed up with the “sealing member”option kit, then the required installation space on that (closed up) side is ·500·mm instead of ·1,500·mm. Item Name 1 Liquid pipe connection port 2 Gas pipe connection port 3 Drain pipe connection 4 Power supply wiring intake 5 Transmission wiring intake hole 6 Air discharge outlet 7 Air suction grille 8 Corner decoration cove 9 Drain hose 10 Knockout hole NOTES 1. Location of nameplate: The unit nameplate is located on the control box cover. The decoration panel nameplate is located on the piping-side panel frame, under the corner cover. 2. When installing optional accessories, refer to their respective documentation. 3. Make sure the distance between the ceiling and the cassette does not exceed ·35·mm. The maximum ceiling opening is ·910·mm. 4. When the conditions in the ceiling exceed 30°C ambient temperature and 80% relative humidity, or when fresh air is inducted into the ceiling, additional insulation is required (polyethylene foam, thickness ≥·10·mm). 5. When installing a sensor kit, there will be a sensor on this location. For details, see the drawing of the sensor kit. (*1) Not applicable to recessed lighting. (*2) Required space for entering with vacuum cleaner tube. (*3) Make sure the decoration panel discharge outlet is not blocked. FXFN-B WITH SELF CLEANING PANEL Detailed technical drawings 4 - M8 or M10 Click here to view all FXFN-B technical drawings on my.daikin.eu

RkJQdWJsaXNoZXIy MTE0MTkzMg==