VRV product catalogue

221 FXFN-B WITH DESIGNER PANEL 2D156547 3D121741D 35 35 340 0-675 4 - M8 M10 3 950 950 8 7 6 AB 213 780 710 420 9 420 Piping side Suspension bolt OR A 55 840 55 B 54.5 54.5 96.5 80 100 100 80 95 350 121.5 25.4 O75 10 350 121.5 54.5 54.5 96.5 81 100 100 85 95 4 1 2 280 330 152 192 AA AC 217 (52) 45 5 860-910 860-910 FXFN-B DESIGNER PANEL 2D156547 DETAIL B ·2· places Opposite side DETAIL A ·2· places Opposite side FXFN40/50/63B2VEB FXFN80B2VEB FXFN40/50/63B2VEB FXFN80B2VEB View ·C· FXFN40/50/63B2VEB FXFN80B2VEB ·300· or less Suspension position Suspension position 4 - M8 or M10 Ceiling-mounted lighting Air fan Other unit ·1,500· or more ·1,500· or more ·1,500· or more ·1,500· or more ·1,500· or more ·200· or more ·200· or more Suspension position Ceiling opening See note ·3·. Respect the distances shown on the figure. See note ·3·. View ·C· See note ·3·. ·1,500· or more Piping side Drain side ·2,000· or more ·4,000· or more See note ·5·. See note ·6·. Ceiling opening See note ·3·. Adjustable ·2,700· or more Required installation space Required installation space If a discharge outlet is closed up with the “sealing member”option kit, then the required installation space on that (closed up) side is ·500·mm instead of ·1,500·mm. NOTES 1. Location of nameplate: The unit nameplate is located on the control box cover. The decoration panel nameplate is located on the piping-side panel frame, under the corner cover. 2. When installing optional accessories, refer to their respective documentation. 3. Make sure the distance between the ceiling and the cassette does not exceed ·35·mm. The maximum ceiling opening is ·910·mm. 4. When the conditions in the ceiling exceed 30°C ambient temperature and 80% relative humidity, or when fresh air is inducted into the ceiling, additional insulation is required (polyethylene foam, thickness ≥·10·mm). 5. When installing a sensor kit, there will be a sensor on this location. For details, see the drawing of the sensor kit. 6. When installing a wireless controller, there will be a receiver on this location. For details, see the drawing of the wireless controller. Item Name 1 Liquid pipe connection port 2 Gas pipe connection port 3 Drain pipe connection 4 Power supply wiring intake 5 Transmission wiring intake hole 6 Air discharge outlet 7 Flat grille assembly 8 Corner decoration cove 9 Drain hose 10 Knockout hole Cassette height Minimal installation height AA AB AC Model 246 180 311 FXFN40/50/63B2VEB 288 180 353 FXFN80B2VEB FXFN-B WITH FRESH AIR INLET KIT Detailed technical drawings NOTES 1. When installing a fresh air intake kit, provide a service access panel. 2. Field construction 3. This corner discharge outlet needs to be closed. 4. When installing a duct fan, use a wiring adapter to link the duct fan to the fan of the indoor unit. 5. The intake air flow rate is recommended to be ≤20% of the air flow rate at high fan speed. If the intake air flow rate is too large, the operating sound may increase, and the detection of the indoor unit suction temperature may be affected. 6. This indicates the distance between the T-joint inlet and the indoor unit inlet when the T-tube is connected. 328 328 427 427 448 508 840 840 55 55 A 1 2 3 4 5 6 0 140 130 120 110 100 90 80 70 60 50 40 30 20 10 725 (1000) 455 O148 180 278 AA O148 AB 320 222 455 3D121741D FXFN-B FRESH AIR INLET KIT Minimal installation height AA AB Model 277 319 FCAG35/50/60/71BVEB FXFQ20/25/32/40/50/63BVEB FXFA20/25/32/40/50/63A2VEB 319 361 FCAG100/125/140BVEB FXFQ80/100BVEB FXFA80/100A2VEB FXFN50/71A2VEB 361 403 FCAHG71/100/125/140HVEB FXFQ125BVEB FXFA125A2VEB FXFN112A2VEB FXFN80B2VEB ARROW VIEW C View ·A· Duct Piping side Drain side See note ·3· Inlet T-joint Designer decoration panel Decoration panel Suction chamber Suction chamber Field supply See note ·6· Ceiling opening Ceiling opening Air flow rate [m³/min] Static pressure in chamber [Pa] See note ·3· Service access panel ·450 x 450 mm· or more Duct Left side Right side See note ·1·. Click here to view all FXFN-B technical drawings on my.daikin.eu

RkJQdWJsaXNoZXIy MTE0MTkzMg==