186 Detailed technical drawings FVA71A FVA100-125-140A B 598 A 0.7 6 6 5 4 6 3 1 9 8 184 184 95 30 330 2 270 314 34 1850 600 677 825 18 200 223 95 541 616 68 130 126 130 215 260 149 57 144 242 10 50 100 50 110 186 44 49 180 50 110 186 100 75 50 46 Ø14 7 253 ± B 598 A 0.7 6 6 5 4 6 3 1 9 184 184 95 30 350 314 34 1850 600 677 825 18 200 223 95 541 616 68 322 10 50 100 130 190 266 260 130 190 266 100 75 50 46 Ø14 253 8 49 44 202 79 260 130 215 130 126 229 2 330 7 ± 3D110397 3D110703 Item Part name Remark 1 Air suction grille 2 Air filter 3 Hole for piping 70 x 90mm oblong holes 4 Hole for piping Knockout hole for recirculation piping or wiring of optional equipment Ø80 5 Hole for piping Knockout hole for recirculation piping or wiring of optional equipment Ø27 6 Piping hole (rear) 80 x 130mm oblong holes 7 Piping hole (bottom) 126 x 130mm oblong holes 8 Liquid pipe Ø9.5 flared connection 9 Gas pipe Ø15.9 flared connection 10 Drain pipe connection VP20 NOTES 1. The unit nameplate is located on the switch box cover, inside the suction grille. Item Part name Remark 1 Air suction grille 2 Air filter 3 Hole for piping 70 x 90mm oblong holes 4 Hole for piping Knockout hole for recirculation piping or wiring of optional equipment Ø80 5 Hole for piping Knockout hole for recirculation piping or wiring of optional equipment Ø27 6 Piping hole (rear) 80 x 130mm oblong holes 7 Piping hole (bottom) 126 x 130mm oblong holes 8 Liquid pipe Ø9.5 flared connection 9 Gas pipe Ø15.9 flared connection 10 Drain pipe connection VP20 NOTES 1. The unit nameplate is located on the switch box cover, inside the suction grille. This unit has to be fixed with fixing screws as shown below. In case of fixing it at the bottom This unit has to be fixed with fixing screws as shown below. In case of fixing it at the bottom Dimension of air lter when pulled out Dimension of air lter when pulled out Pull-out direction of air lter Pull-out direction of air lter 740 or more 740 or more Position of fully opened suction grille Position of fully opened suction grille 2-7 x 15mm oblong holes 2-7 x 15mm oblong holes Fixture for preventing overturning Fixture for preventing overturning Suction grille stopper Suction grille stopper DETAIL A Both sides identical DETAIL A Both sides identical View B View B 4 holes for anchor bolts 4 holes for anchor bolts Required installation space Required installation space 1,500 or more 1,500 or more 50 or more 50 or more 50 or more 50 or more Accessory Accessory In case vibration resistance is required, fix it at both the bottom and the rear. In case vibration resistance is required, fix it at both the bottom and the rear. Click here to view all FVA-A technical drawings on my.daikin.eu
RkJQdWJsaXNoZXIy MTE0MTkzMg==